Polyaxial locking plate fixation in distal femur fractures: a biomechanical comparison.
نویسندگان
چکیده
OBJECTIVES Uniaxial, first-generation locking plates have become increasingly popular for fixation of supracondylar femur fractures. Polyaxial plates are currently available, which allow for variable-angle screw insertion; however, the biomechanical integrity of these new locking constructs is yet unproven. This study compares the mechanical stability of a conventional locking plate with that of a new polyaxial design. METHODS A comminuted supracondylar femur fracture (AO/OTA33-A3) gap model was created in fourth-generation synthetic composite bones. Fixation was obtained with 2 different plate constructs: (1) a conventional locking plate (uniaxial screw heads threading directly into plate) and (2) a polyaxial locking plate (screw heads are captured and "locked" into a fixed angle using locking caps). Eight specimens of each type were then tested in axial, torsional, and cyclic axial modes on a material testing machine. RESULTS The mean axial stiffness for the polyaxial locking plate was 24.4% greater than the conventional locking plate (168.2 vs 127.1 N/mm; P < 0.0001). The mean torsional stiffness was also greater for the polyaxial plate (2.78 vs 2.57 Nm/degree; P = 0.0226). Cyclic axial loading caused significantly less (P = 0.0034) mean irreversible deformation in the polyaxial plate (5.6 mm) than in the conventional plate (8.8 mm). The mean ultimate load to failure was significantly higher (P = 0.0005) for the polyaxial plate (1560 N) than for the conventional plate (1337 N). CONCLUSIONS The tested plate construct with its polyaxial locking screw mechanism provides a biomechanically sound fixation option for supracondylar femur fractures. The frictional locking mechanism allows maintenance of angular stability while affording the option of variable screw placement.
منابع مشابه
Mono- versus polyaxial locking plates in distal femur fractures – a biomechanical comparison of the Non-Contact-Bridging- (NCB) and the PERILOC-plate
BACKGROUND The aim of this cadaveric study was to compare a polyaxial (NCB®, Zimmer) to a fixed-angle monoaxial locking plate (PERILOC®, Smith & Nephew) in comminuted fractures of the distal femur regarding stability of the construct. Up to date there is no published biomechanical data concerning polyaxial plating in cadaveric distal femurs. METHODS Fourteen formalin fixed femora were scanned...
متن کاملConstruction and Biomechanical Properties of PolyAxial Self-Locking Anatomical Plate Based on the Geometry of Distal Tibia
In order to provide scientific and empirical evidence for the clinical application of the polyaxial self-locking anatomical plate, 80 human tibias from healthy adults were scanned by spiral CT and their three-dimensional images were reconstructed using the surface shaded display (SSD) method. Firstly, based on the geometric data of distal tibia, a polyaxial self-locking anatomical plate for dis...
متن کاملPeri-Implant Fractures Distal to an Antegrade Femoral Nail: A Case Series
Peri-implant fractures distal to an antegrade femoral nail are uncommon injuries, with no current consensus on the best treatment modality. We are presenting three cases of periimplant fractures distal to an antegrade femoral nail. All patients sustained an initial traumatic injury, which was managed with an antegrade femoral nail fixation. They subsequently suffer a second injury which causes ...
متن کاملA Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate
Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...
متن کاملResults in treatment of distal femur fractures using polyaxial locking plate
Indications and techniques of locked plate fixation for the treatment of challenging fractures continue to evolve. As design variant of classic locked plates, the polyaxial locked plate has the ability to alter the screw angle and thereby, enhance fracture fixation. The aim of this observational study was to evaluate clinical and radiographic results in 89 patients with 90 fractures of the dist...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of orthopaedic trauma
دوره 22 9 شماره
صفحات -
تاریخ انتشار 2008