[Development of posture measuring apparatus using goniometer and inclinometer. 2. Fixation, precision and calibration of goniometer].

نویسندگان

  • A Seo
  • T Seo
  • M Kakehashi
  • F Yoshinaga
چکیده

A new posture measuring apparatus was developed for time and motion study in the field of industrial health. This apparatus records working postures by measuring angles of joints and trunk inclination. The angles of joints were measured by the newly developed goniometers which use the bending loss of rubber optical fibers. This paper presents results of studies made on the fixation, precision and calibration of goniometers which are important in the actual application of this apparatus. Six freedoms of five joints were examined, i.e. elbow (flexion/extension), shoulder (abduction/adduction and horizontal adduction/abduction), hip (flexion/extension), knee (flexion/extension), ankle (dorsi-flexion/plantar-flexion). The results obtained were as follows; 1) Goniometers should be fixed according to the characteristics of each joint. 2) The output errors were calculated from the measured data, excluding the effects of flexed angles, subjects and fixations. The mean output error of all joints was 0.189 V (14.3 degree). 3) The output errors by the three calibration methods using logistic curves were calculated. The output errors for 2-point method (calibrated by the data of minimum and maximum angles) and 3-point method (calibrated by the data of minimum, medium and maximum angles) were 1.34 and 1.22 times larger than the output errors (0.139 V) for all-point method (calibrated by all measured data), respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intra- and inter-examiner reliability of goniometer and inclinometer use in Craig’s test

[Purpose] The purpose of this study was to determine the inter- and intra-examiner reliability of measurement methods for femoral anterversion during Craig's test. [Subjects and Methods] The study included 37 healthy participants (20 males and 17 females). Two novice examiners (Department of Physical Therapy students at Silla University) used three different methods to measure the femoral anter...

متن کامل

Reliability of goniometric measurements in children with cerebral palsy: A comparative analysis of universal goniometer and electronic inclinometer. A pilot study

BACKGROUND Even though technological progress has provided us with more and more sophisticated equipment for making goniometric measurements, the most commonly used clinical tools are still the universal goniometer and, to a lesser extent, the inclinometer. There is, however, no published study so far that uses an inclinometer for measurements in children with cerebral palsy (CP). The objective...

متن کامل

The reliability and concurrent validity of scapular plane shoulder elevation measurements using a digital inclinometer and goniometer.

This study investigated the reliability and concurrent validity of active shoulder elevation in the scapular plane (scaption) using a digital inclinometer and goniometer. Two investigators used a goniometer and digital inclinometer to measure scaption on 30 asymptomatic participants in a blinded repeated measures design. Good reliability was present with intraclass correlation coefficients (ICC...

متن کامل

Three methods for measuring range of motion while wearing protective clothing: A comparative study

This paper evaluates three methods for objectively measuring ROM while workers are wearing protective clothing: a universal goniometer, a Leighton Flexometer, and an electrogoniometer. Ten male subjects performed a set of nine gross body movements while semi-nude and while wearing each of nine configurations of coveralls. Coveralls varied in relative size and fabric weight, Changes in joint ang...

متن کامل

Measuring the Quadriceps Angle by a New Method and Comparison with Goniometer and Radiography

Objective: The purpose of this study is to decrease the amount of error when measuring Q–angles using a goniometer by the new method, a private system developed at the I.R;#39s university of social welfare & rehabilitation sciences (USWR) by Investigator. Materials & Methods: Fourty subjects with Eighty healthy knees participated in this methodologic study. One investigator participated in d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Sangyo igaku. Japanese journal of industrial health

دوره 34 3  شماره 

صفحات  -

تاریخ انتشار 1992