Efficient " water window " soft x - ray high - Z plasma

نویسندگان

  • Gerry O’Sullivan
  • Tao Wu
  • Takeshi Higashiguchi
  • Bowen Li
  • G O’Sullivan
چکیده

Unresolved transition array (UTA) is scalable to shorter wavelengths, and we demonstrate a table-top broadband emission “water window” soft x-ray source based on laserproduced plasmas. Resonance emission from multiply charged ions merges to produce intense UTAs in the 2 to 4 nm region, extending below the carbon K edge (4.37 nm). An outline of a microscope design for single-shot live cell imaging is proposed based on a bismuth (Bi) plasma UTA source, coupled to multilayer mirror optics.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimum driving a Z-pinch for soft X-Ray lasers

A capillary plasma z-pinch as an alternative active medium of soft X-Ray lasers was studied experimentally and theoretically. The theoretical analysis was based on the self consistent solution of the so called “snow plow” model. The dynamics of pinched plasma is determined by the capillary parameters and by the time dependence of electrical current passing through it. The current time dependenc...

متن کامل

Liquid-jet target for laser-plasma soft x-ray generation

We describe a new liquid-target system for low-debris laser-plasma soft x-ray sources. The system is based on a microscopic liquid jet and is experimentally evaluated for 0.7–1 keV proximity lithography and water-window x-ray microscopy applications. Compared to an existing liquid-droplet target, this target system has the same low debris emission, high x-ray photon flux, and narrow spectral ba...

متن کامل

Target optimization of a water-window liquid-jet laser–plasma source

We optimize the water-window x-ray flux and debris deposition for a liquid-jet laser plasma source by varying both the target diameter and the jet material. For two target liquids, methanol and ethanol, measurements of the l53.37 nm C VI x-ray flux and the debris deposition rates are presented as function of the jet diameter. It is shown that the effective carbon debris deposition is more than ...

متن کامل

Compact water-window transmission X-ray microscopy.

We demonstrate sub-100 nm resolution water-window soft X-ray full-field transmission microscopy with a compact system. The microscope operates at lambda = 3.37 nm and is based on a 100 Hz table-top regenerative debris-free droplet-target laser-plasma X-ray source in combination with normal-incidence multilayer condenser optics for sample illumination. High-spatial-resolution imaging is performe...

متن کامل

Design and performance of a laser-plasma-based compact soft x-ray microscope

We describe the design of a user-friendly compact water-window x-ray microscope. The microscope is based on a l53.37 nm liquid-jet-target laser-plasma source in combination with a normal-incidence multilayer condenser mirror and high-resolution diffractive optics for the imaging. With its high mechanical and thermal stability, the instrument demonstrates enhanced resolution and potential for co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012