Conditioning data for calculation of the modulation transfer function.

نویسندگان

  • Andrew D A Maidment
  • Michael Albert
چکیده

A method for conditioning data used in the measurement of the modulation transfer function (MTF) is discussed. This method is based upon imposing the constraint that the edge spread function (ESF) is monotonic. The advantages of this technique, when applicable, are demonstrated with simulated examples for which the true MTF is known. The application of this technique in the measurement of the MTF of a digital detector in clinical use is also demonstrated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Fabrication Process of MTF Phantom CT Scan

Introduction: One of the main steps in the optimization process in diagnostic imaging is the quality control of radiology devices. The usual method of CT scan calibration is used of a phantom. The phantom created a certain weakening for the radiation through which it passes. One of the most suitable methods for quantitative analysis of the resolution and contrast in CT scan im...

متن کامل

Analytical Investigation of Frequency Behavior in Tunnel Injection Quantum Dot VCSEL

The frequency behavior of the tunnel injection quantum dot vertical cavitysurface emitting laser (TIQD-VCSEL) is investigated by using an analyticalnumericalmethod on the modulation transfer function. The function is based on therate equations and is decomposed into components related to different energy levelsinside the quantum dot and injection well. In this way, the effect of the tunnelingpr...

متن کامل

Investigation of the Spatial Resolution of MR-Based Polymer Gel Dosimetry versus Film Densitometry using Dose Modulation Transfer Function

Introduction: The conventional methods of dosimetry are not capable of dosimetry in such a small volume of less than one cubic millimeter. Although the polymer gel dosimetry method based on magnetic resonance imaging (MRI) could achieve three dimensional dosimetry with high resolution, a spatial resolution evaluation based on gel dose modulation transfer function has not been investigated yet. ...

متن کامل

Thermal conductivity calculation of magnetite using molecular dynamics simulation

In the current research, thermal conductivity of magnetite (Fe3O4) has been calculated using molecular dynamic simulation. The rNEMD Molecular Dynamics Method provided in the LMMPS package is used for the simulation of the thermal conductivity. The effects of magnetite layer size and temperature on the thermal conductivity have been investigated. The numerical results have...

متن کامل

Absolute Acceleration Transfer Function of Secondary Systems Subjected to Multi- Component Earthquakes

The importance of the equipment and secondary systems in seismic design and performance evaluation is well recognized and has been the subject of many studies. In all of these studies, earthquake is considered as a single component, and in most of them the primary system is considered as shear building. Most attention has been concentrated on the response of secondary system and its response sp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 30 2  شماره 

صفحات  -

تاریخ انتشار 2003