Volatile Toluene and Xylene Removal Efficiency of Foliage Plants as Affected by Top to Root Zone Size
نویسندگان
چکیده
Phytoremediation of volatile organic compounds in indoor air involves both the plant and microbes in the media; however, removal rate is typically expressed on a leaf area basis. We determined the effect of root media volume on phytoremediation rate of volatile toluene and xylene to determine if there is a change in phytoremediation efficiency. Phytoremediation rate was calculated based on the aboveground space occupied by the plant and on the leaf area. Foliage plants of Fatsia japonica and Draceana fragrans ‘Massangeana’ were grown in different-sized pots (1, 2, 4, 6, and 12 L) that gave aerial plant to root zone volume ratios of 21:1, 21:2, 21:3, and 21:6. Total root volume and root fresh weight increased in D. fragrans with increasing media volume, whereas root density per unit of media volume decreased in both species. The efficiency of volatile toluene and xylene removal by the plants was increased as the root zone volume increased, whereas removal efficiency per unit media volume increased and then decreased. The highest volatile toluene and xylene removal efficiency was at a ratio of 21:3 (aerial plant:root zone volume) in F. japonica and 21:2 in D. fragrans. When phytoremediation efficiency was expressed on a leaf area basis, the phytoremediation rate for toluene and xylene increased progressively for both species with increasing media volume and as root volume increased. Calculating the amount of plant material needed within a home or office to obtain sufficient volatile organic compound (VOC) removal cannot be accurately predicted base solely on a leaf area (LA) or aboveground volume basis. Indoor plants can remove VOCs from the air in homes and offices, some of which are known to be highly toxic. The rate of removal (generally expressed on a LA basis as mg·m·m·h) is known to differ substantially among species (Kays, 2011); and as the plant size increases, the removal potential per plant increases. The amount of plant material needed to reduce the VOC concentration within a structure varies with the steady-state VOC concentration, air exchange rate of the building, VOC removal rate of the plant species selected, percent reduction in concentration desired, and the plant mass present, among other factors (e.g., temperature, light intensity). The acceptable number of plants that can be placed in a building depends on a range of factors, among which the physical volume of the building and the volume of space occupied per plant are critical. The relationship between the aboveground size of the plant and its VOC removal potential is further complicated by the fact that microorganisms in the root zone eliminate a substantial amount of VOCs during both the day and night. The ratio of formaldehyde removed by aerial plant parts vs. the root zone was 1:1 during the day but declined to 1:11 at night when the stomata are closed (Kim et al., 2008). Wolverton and Wolverton (1993) found that the top to media VOC removal ratio also varied with plant species and the VOC in question. During the day, Dieffenbachia seguine (Jacq.) Schott var. seguine (syn. D. maculata) and Nephrolepis exaltata (L.) Schott had similar ratios ( 1:1 aerial plant parts:root zone) for xylene, whereas ratios for formaldehyde favored the root zone (37:63 Dieffenbachia sp. to 40:60 Aglaonema sp.). The root zone, therefore, accounts for 50% or greater of the total VOCs removed during the day and the majority (greater than 90%) during the night. When estimating the potential rate of VOC removal with plants having differing aerial plant and root zone volume ratios, the assumption is that LA accurately reflects the rate; however, different media volumes may significantly impact the contribution by microbes. To test this assumption, we assessed the VOC removal efficiency of plants as rate/aboveground volume to media volume ratio and rate/LA to media volume and root volume ratios using plants of about equal size that were growing in pots of differing diameters and media volumes. Materials and Methods Plant materials. Fatsia japonica (Thunb.) Decne. & Planch. and Dracaena fragrans (L.) Ker Gawl. cv. Massangeana foliage plants were obtained from a commercial market. F. japonica and D. fragrans were selected as woody species with fibrous roots and a central tap root, respectively. The three-dimensional volume occupied by the aerial portion of the plant was calculated assuming they were cylindrical as v = prh with the radius (r) and height (h). The plants were transplanted into pots specifically fabricated for the experiment (Fig. 1), containing a uniform growing medium [i.e., Mix #4 (Sun Gro Horticulture, Bellevue, WA), bark-humus (Biocom. Co., Seoul, Korea), and sand at 5:1:1, v/v/v]. Mix #4 contained Canadian sphagnum peat moss (55% to 65% by volume), perlite, dolomitic lime, gypsum, and a wetting agent. All plants were grown in a greenhouse for 5 months after transplanting. The pots were 1, 2, 4, 6, and 12 (L) in volume (Fig. 2). All pots were 20 cm in height and had growing medium filled to a height of 16 cm. To maximize the accuracy of determining the air space volume occupied by each plant, nine pot plants were arranged as a square and the width measured, which was divided by three to obtain the average radius of each plant (Kim and Lee, 2008); the height was measured from the media surface to the top of the leaves. The air space volume of the aboveground portion of F. japonica plants was 21 L; they were planted in 1-, 2-, 4-, and 6-L pots. D. fragrans plants (42 L) were planted in 2-, 4-, 6-, and 12-L pots. Each species had identical aboveground to media volume ratios for the various pot sizes of 21:1, 21:2, 21:3, and 21:6. The plants were acclimated within the indoor environment used for the experiments for 1 month (23 ± 2 C, 40% ± 5% relative humidity, 20 ± 2 mmol·m·s photosynthetically active radiation, and a 12-h photoperiod). The plants were watered every 3 d with the excess water allowed to drain. All plants were watered the day before the gas treatments. Three pots of each pot size were placed in a chamber. Three replicates (chambers) of each treatment were tested. Chambers without plants were used to determine toluene and xylene losses not resulting from the plants (e.g., leakage, adsorption, chemical reactions). After removal of the media, the root volume was measured using water displacement in a 2-L graduated cylinder (Fig. 3) with root density calculated as root volume divided by media volume. Leaf area was determined using a LI-3100 leaf area meter (LI-COR Inc., Lincoln, NE) at the end of the experiment (root and LA data are presented in Table 1). Treatment system. The treatment system consisted of controlled-environment rooms (i.e., temperature, light intensity, and relative humidity) containing the test chambers and a gas generator. The test chambers, described by Kim et al. (2011), were 1.0 m (90 · 90 · 123 cm) and impervious to VOCs. Interior air Received for publication 24 Sept. 2013. Accepted for publication 9 Dec. 2013. To whom reprint requests should be addressed; e-mail [email protected]. 230 HORTSCIENCE VOL. 49(2) FEBRUARY 2014 was circulated (6 L·min) and tested for toluene and xylene concentration at three positions: 12, 70, and 98 cm above the base of the chamber. Gas exposure and measurement. The plants were pretreated with toluene and xylene, which is known to enhance their phytoremediation potential for each gas. Gaseous toluene and xylene were introduced into test chambers containing plants as previously described (Kim et al., 2011) and allowed to equilibrate for 15 min. The internal concentration was determined and corrected to 2.0 mL·L for the stimulation treatment. The plants remained in the stimulation treatment for 12 h and then were moved to fresh air for 12 h. After the stimulation treatment, the subsequent toluene and xylene removal rate by the plants was determined. Time 0 was after 12 h in fresh air after the toluene and xylene stimulation treatment. The plants were exposed at 1.0 mL·L of each gas and the rate of toluene and xylene removal measured within the chambers after 6 and 12 h (Kim et al., 2011). Changes in toluene or xylene concentration within the chambers were expressed as cumulative removal on a LA basis (mg·m·m) and as the rate of removal (mg·m·m·h). Chambers devoid of plants were treated similarly to determine gas losses resulting from chamber effects. Toluene and xylene quantification. Air samples were collected at the appropriate time intervals using a quartz cold trap [120 mm long, 2.9 mm o.d., 1.0 mm i.d. (inlet), 2.0 mm i.d. (outlet); Markes International Ltd., Llantrisant, U.K.] connected to each chamber with the air collected for 5 min at 5 mL·min. An automated thermal desorption system with Air Server autosampler (UNITY; Markes International Ltd.) was connected to the injection port of the gas chromatograph–mass spectrometer (TRACE DSQ; Thermo Electron Co., Waltham, MA). The desorbed sample was cryofocused at 5 C for 5 min on the first few centimeters of the column, desorbed at 280 C, and separated using a ZB-624 capillary column (30 m length, 0.25 mm i.d., 1.40 mm film thickness of 6% cyanopropylphenyl, 94% dimethylpolysiloxane; Phenomenex, Torrance, CA). The injection port temperature was 180 C with a split ratio of 29:1. Helium was used as the carrier gas at a flow rate of 1.0 mL·min. The column temperature was held at 45 C for 1 min and increased at a rate of 15 C·min to 100 C and held for 1 min and then increased at a rate of 5 C·min to 135 C. Table 1. Root and leaf area data for foliage plants grown at different aerial plant to root zone volume ratios. Species Aerial plant to root zone volume ratios Root Leaf area (m/pot) Volume (mL/pot) Density (mL·L soil volume) Fresh wt (g/pot) F. japonica 21:1 36.9 ± 1.5 36.9 ± 1.5 40.0 ± 2.3 1.6 ± 0.05 21:2 37.1 ± 1.1 18.6 ± 0.6 41.1 ± 0.6 1.3 ± 0.04 21:3 38.1 ± 4.5 12.7 ± 1.5 43.2 ± 5.9 1.4 ± 0.09 21:6 37.3 ± 2.0 6.2 ± 0.3 42.6 ± 1.1 1.6 ± 0.01 D. fragrans 21:1 60.8 ± 3.3 30.4 ± 1.7 62.1 ± 2.4 3.6 ± 0.27 21:2 70.2 ± 3.4 17.6 ± 0.9 70.1 ± 5.5 3.6 ± 0.26 21:3 80.8 ± 2.2 13.5 ± 0.4 86.6 ± 4.2 3.9 ± 0.35 21:6 113.3 ± 5.9 9.4 ± 0.5 111.7 ± 4.0 3.9 ± 0.35 Fig. 1. Dracaena fragrans plants after growing 6 months in four different media volumes (1, 2, 4, 6 L/pot). Fig. 2. Pots fabricated for test were 1, 2, 4, 6, and 12 L in volume and 20 cm high with the growing medium filled to 16 cm from the base. Fig. 3. Isolated roots of Draceana fragrans plants grown in pots that were 2, 4, 6 and 12 L in volume gave aerial plant to root zone volume ratios of 21:1, 21:2, 21:3, and 21:6, respectively. Root volume was determined by water displacement. HORTSCIENCE VOL. 49(2) FEBRUARY 2014 231 MISCELLANEOUS
منابع مشابه
Phytoremediation of benzene, toluene, ethylbenzene and xylene contaminated air by D. deremensis and O. microdasys plants
BACKGROUND People usually spent about 90% of their time indoors, which are probably more polluted than outside the buildings. High levels of volatile organic compounds (VOCs) are known as causes of sick building syndrome. The present study was designed to determine the quantitative effects of some plants to improve the quality of the environmental air. RESULTS D. deremensis and O. microdasys ...
متن کاملبررسی کارایی زئولیت کلینوپتیلولیت اصلاح شده و کلینوپتیلولیت اصلاح شده حاوی نانوذرات اکسید مس در حذف ترکیبات BTX از هوا
Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 Background and Objectives:Benzene, toluene and Xylenes (BTX) are organic pollutants, which are mainly associated with oil and its derivatives. BTX is environmental contaminants and considered harmful to human heal...
متن کاملStudy of the removal difference in indoor particulate matter and volatile organic compounds through the application of plants
This study was conducted to evaluate the ability of plants to purify indoor air by observing the effective reduction rate among pollutant types of particulate matter (PM) and volatile organic compounds (VOCs). PM and four types of VOCs were measured in a new building that is less than three years old and under three different conditions: before applying the plant, after applying the plant, and ...
متن کاملCancer Risk Assessment Benzene, Toluene, Ethylbenzene and Xylene (BTEX) in the Production of Insulation Bituminous
Benzene, Toluene, Ethyl Benzene and Xylene are volatile organic compounds (VOCs) with approximately similar physical and chemical characteristics. Benzene and Ethyl-benzene are known carcinogen as well as they affect the circulatory, nervous, and reproductive and respiratory systems. Toluene and Xylene also damage the nervous and reproductive systems. The main purpose of this study is to determ...
متن کاملبهینه سازی بیوراکتور دوفازی همزندار به منظور حذف بخارات بنزن، تولوئن و زایلن(BTX) از جریان هوا
Introduction: In real Conditions, pollution emission are mostly released as mixed components rather than a single pure emission of the chemicals. In this study, a miniature stirred tank bioreactor was optimized for treatment of waste gas containing BTX (benzene, toluene and xylene). . Material and Method: The sludge of an oil refinery was sampled based on the assumption that it contains BTX-d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2014