Vapor phase tri-methyl-indium seeding system suitable for high temperature spectroscopy and thermometry.
نویسندگان
چکیده
Tri-methyl-indium (TMI) is used as an indium transport molecule to introduce indium atoms to reactive hot gas flows/combustion environments for spectroscopic diagnostics. A seeding system was constructed to allow the addition of an inert TMI laden carrier gas into an air/fuel mixture burning consequently on a burner. The amount of the seeded TMI in the carrier gas can be readily varied by controlling the vapor pressure through the temperature of the container. The seeding process was calibrated using the fluorescent emission intensity from the indium 6(2)S1/2 → 5(2)P1/2 and 6(2)S1/2 → 5(2)P3/2 transitions as a function of the calculated TMI seeding concentration over a range of 2-45 ppm. The response was found to be linear over the range 3-22.5 ppm; at concentrations above 25 ppm there is a loss of linearity attributable to self-absorption or loss of saturation of TMI vapor pressure in the carrier gas flow. When TMI was introduced into a post-combustion environment via an inert carrier gas, molecular transition from InH and InOH radicals were observed in the flame emission spectrum. Combined laser-induced fluorescence and absorption spectroscopy were applied to detect indium atoms in the TMI seeded flame and the measured atomic indium concentration was found to be at the ppm level. This method of seeding organometallic vapor like TMI to a reactive gas flow demonstrates the feasibility for quantitative spectroscopic investigations that may be applicable in various fields, e.g., chemical vapor deposition applications or temperature measurement in flames with two-line atomic fluorescence.
منابع مشابه
Applications and evaluation of two-line atomic LIF thermometry in sooting combustion environments
Temperature measurements using planar laser-induced fluorescence (PLIF) are most often associated with experimental challenges. In addition, no PLIF technique is generally applicable in all kinds of environment. Especially under sooting conditions problems are prone to arise, which limits the use of these techniques. In this paper the two-line atomic fluorescence (TLAF) technique was investigat...
متن کاملThe Effect of pH on the Liquid-liquid Equilibrium for a System Containing Polyethylene Glycol Di-methyl Ether and Tri-potassium Citrate and its Application for Acetaminophen Separation
In this work liquid-liquid equilibrium for aqueous two phase system composed of polyethylene glycol di-methyl ether and tri-potassium citrate at different medium pH values (6.00, 7.00 and 8.00) and 298.15 K was studied. The obtained results show that two phase area expanded with an increasing of pH values. The performances of the Merchuk and semi-empirical equations were tested in correlating t...
متن کاملThe Kelvin and Temperature Measurements
The International Temperature Scale of 1990 (ITS-90) is defined from 0.65 K upwards to the highest temperature measurable by spectral radiation thermometry, the radiation thermometry being based on the Planck radiation law. When it was developed, the ITS-90 represented thermodynamic temperatures as closely as possible. Part I of this paper describes the realization of contact thermometry up to ...
متن کاملDiode laser atomic fluorescence temperature measurements in low-pressure flames
Temperature measurements have been performed in a low-pressure flame by the technique of diode laser induced atomic fluorescence. The experiments were done in a near-stoichiometric flat-flame of premixed methane, oxygen and nitrogen, at a pressure of 5.3 kPa. Indium atoms were seeded to the flame and probed using blue diode lasers; the lineshapes of the resulting fluorescence spectra were used ...
متن کاملDiode laser induced fluorescence spectroscopy for combustion thermometry
This paper describes the first use of novel blue diode lasers to make temperature measurements based on fluorescence. As a demonstration of this principle, indium atoms were seeded as a probe species into flames and the resulting diode laser induced fluorescence allowed an accurate determination of the temperature at a point. This permits spatially resolved measurements to be made, which are im...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 86 9 شماره
صفحات -
تاریخ انتشار 2015