A modified method for the quantitative determination of the thymol turbidity reaction of serum.

نویسندگان

  • R E SHANK
  • C L HOAGLAND
چکیده

It was observed by Maclagan that turbidity is produced in a barbital buffer saturated with thymol when specimens of serum from patients with diseases of the liver are added (1, 2). The degree of turbidity apparently varied with the degree of hepatic parenchymal damage. An analysis of the precipitate demonstrated that it contained globulin, phospholipid, cholesterol, and thymol. The mechanism of the reaction is unexplained, but there is some evidence to indicate that the reaction may be due to an abnormal globulin released into the blood stream in the presence of liver damage. The determination of thymol turbidity had been found useful in estimating the degree of hepatic damage in patients with diseases of the liver and in pathological states experimentally produced in animals. In the original technique the amount of turbidity was estimated by visual comparison with the gelatin standards of Kingsbury et al. (3), which were devised for the estimation of urinary albumin. This method is subject to all of the usual criticisms of visual methods for calorimetric and nephelometric measurements. In the presence of hemolysis and of increased concentrations of bilirubin in the serum, accurate measurements of turbidity may be difficult to obtain. Moreover, the preparation and maintenance of adequate gelatin standards are associated with some difficulty. In order to obtain objective and more accurate quantitative measurement of turbidity, and to permit rigid standardization of the technique, the method has been modified in this laboratory so that turbidimetric determinations may be made in the spectrophotometer with a suspension of barium sulfate as a standard.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A study of the thymol turbidity test with special reference to buffer behavior. Formulation of a modified reagent using tris-hydroxymethylaminomethane.

Replacement of barbiturate buffer by a tris-hydroxymethylaminomethane buffer in the thymol test reagent of Maclagan greatly improves the stability of the reagent. Thymol turbidity measurements made by means of the modified reagent agreed closely with those made with barbiturate-containing reagents. However in hyperlipemic sera, the latter reagent gave higher turbidities. A reaction of barbitura...

متن کامل

Mechanism and Significance of the Thymol Turbidity Test for Liver Disease.

An increase in the amounts of the globulin components of the serum has long been recognized in advanced states of liver disease (1, 2, 3), although the significance of the alteration has never been defined. It has been the basis of the Takata-Ara, Weltmann and the formol-gel reactions which have been used for many years in the diagnosis of liver disease. The nonspecific nature of these tests is...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

Qualitative and Quantitative Approaches for Determination of Hemolyzed Serum

Abstract Background and Objective: Prevention of medical laboratory errors is a major goal of quality control programs. Hemolyzed specimen is one of the common issues causing medical laboratory errors. Apart from the visual assessment, the measurement of serum hemoglobin concentration can be another method to evaluate the intensity of hemolysis. We aimed to assess hemolyzed serum s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of biological chemistry

دوره 162  شماره 

صفحات  -

تاریخ انتشار 1946