Did the use of the Guideliner V2(TM) guide catheter extension increase complications? A review of the incidence of complications related to the use of the V2 catheter, the influence of right brachiocephalic arterial anatomy and the redesign of the V3(TM) Guideliner and clinical outcomes.

نویسندگان

  • Mohammad Alkhalil
  • Alison Smyth
  • Simon J Walsh
  • Conor McQuillan
  • Mark S Spence
  • Colum G Owens
  • Colm G Hanratty
چکیده

OBJECTIVE We sought to investigate the incidence of complications associated with V2 Guideliner, understand the mechanisms and evaluate the impact of alterations made to the V3 Guideliner. METHODS Retrospective analysis of consecutive cases employing V2 Guideliner from two university teaching hospitals. Complications were identified, analysed and classified into major versus minor ones. To understand the potential anatomical mechanism of these complications, analysis of normal great vessel anatomy was undertaken in separate cohort of patients undergoing cardiac catheterisation via right radial approach. Further analysis of consecutive cases employing V3 Gudieliner took place and the incidence of complications were compared between V2 and V3 groups. RESULTS Total of 188 cases of V2 Guideliner use were identified. One major complication was reported (coronary dissection). Proximal collar interaction and stent damage occurred in 19 cases (10%). Anatomical data suggest that extending the V2 Guideliner tubing sited the proximal collar of the device in the brachiocephalic/subclavian artery, a potential site of tortuosity and potential cause of the Guideliner proximal collar-stent interaction. Further analysis of 124 cases of V3 Guideliner use demonstrated no cases with proximal collar-stent interactions, one case of longitudinal stent deformation and two incidents of stent interaction with the distal edge of the V3 Guideliner. CONCLUSIONS We have demonstrated a higher incidence of V2 Guideliner complications compared to previous series. The change in design of the V2 Guideliner was a likely contributor but the modifications with V3 Guideliner appear to have ameliorated this issue.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing the Effect of Continuous and Intermittent Irrigation Techniques on Complications of Arterial Catheter and Partial Thromboplastin Time in Patients Following Coronary Artery Bypass Grafting Surgery

Background: Different approaches are available to irrigate the arterial catheter, such as continuous and intermittent techniques. However, there is a disagreement regarding the most appropriate method. Aim: this study aimed to compare the effect of two continuous and intermittent irrigation methods on complications of arterial catheter and partial thromboplastin time (PTT) in patients with coro...

متن کامل

Review of recommendations to prevent and reduce catheter-related bloodstream infections

ABSTRACT Aim. We sought to review studies regarding interventions to prevent or reduce catheter-related bloodstream infections (CRBSIs). Background. CRBSIs are associated with peripheral and central intravenous catheters, including nontunneled central catheters, tunneled central catheters, peripherally inserted central venous catheters (PICC), totally implanted intravascular access devices (por...

متن کامل

Comparing the anatomy of the intrathoracic systemic central venous system in Iranian pediatrics and adults based on chest CT scan and evaluation of rate of catheter malposition in children

Background: Central venous catheterization is a procedure that is being performed frequently especially in critical clinical settings. In such conditions, good knowledge of the surface anatomy of venous structures is vital to avoid possible complications which could result in life-threatening situations such as bleeding and pneumothorax. Considering the difference between venous anatomy of chil...

متن کامل

GuideLiner catheter application in complex coronary lesions: experience of two centers

OBJECTIVE GuideLiner catheter provides adequate back-up support and a coaxial guide engagement for stent delivery in complex coronary anatomies. In this study, we aimed to present one of the largest series of experience with GuideLiner catheter utilized for challenging percutaneous coronary interventions in two centers. METHODS We retrospectively collected the coronary angiography records of ...

متن کامل

Comparing the early function and complications between fluoroscopic guidance and blindly insertion of permanent hemodialysis catheter

Objective: Chronic kidney disease (CKD) is a complicated kidney defect causing permanent failure in renal function in progressive stages. Hemodialysis is the most accepted treatment to maintain body’s fluid/electrolyte homeostasis at the terminal stages of the disease. Permanent hemodialysis catheter (permicath) may be inserted blindly or by fluoroscopic guidance. This study aimed to compare th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Open heart

دوره 3 1  شماره 

صفحات  -

تاریخ انتشار 2016