An improved reagent system for the measurement of serum uric acid.
نویسندگان
چکیده
The reagent is modified as follows: Serum chromogens are destroyed by trisodium phosphate. The use of phosphotungstic acid eliminates the tungstate and sulfate anions, a frequent cause of turbidity. Triethanolamine, added to the carbonate-urea mixture, provides unusual stability of the color through its buffering action. Only 0.2 ml of serum is required. The method is highly reproducible and accurate; analytical results agree closely with those obtained by the uricase or cyanide-urea method.
منابع مشابه
Simultaneous Voltammetric Measurement of Ascorbic Acid, Epinephrine, Uric Acid and Tyrosine at a Glassy Carbon Electrode Modified with Nanozeolite-Multiwall Carbon Nanotube
In this study, incorporation of iron ion-doped natrolite nanozeolite, multi-wall carbon nanotubes into chitosan-coated glassy carbon electrode for the simultaneous determination of ascorbic acid, epinephrine, uric acid and tyrosine is studied. The results show that the combination of multi-wall carbon nanotubes and iron ion-doped natrolite zeolite causes a dramatic enhancement in the sensitivit...
متن کاملUse of 3,5-dichloro-2-hydroxybenzenesulfonic acid/4-aminophenazone chromogenic system in direct enzymic assay of uric acid in serum and urine.
A new direct colorimetric procedure for uric acid assay in serum or urine is described, utilizing a 3,5-dichloro-2-hydroxybenzene sulfonic acid/4-aminophenazone chromogenic system in the presence of horseradish peroxidase and uricase from Aspergillus flavus. This chromogen system has a high absorptivity, affording useful results with sample/reagent volume ratios as low as 0.025. The procedure i...
متن کاملReagent - Strip Urinalysesfor Glucose
deficiency. It is not applicable to newborn or mass screening with use of ifiterpaper specimens, but is satisfactory for liquid urine screening. In one variant of sulfite oxidase deficiency, due to a defect of its molybdate cofactor metabolism, the concentration of uric acid in serum is decreased. Thus, an unexplained low serum uric acid, especially in a young patient with neurologic abnormalit...
متن کاملبررسی میزان سطح اسید اوریک سرمی و شدت درگیری عروق کرونر در آنژیوگرافی در بیماران مبتلا به chronic Stable Angina
Background and purpose: Coronary artery disease (CAD) is the first cause of death in modern societies. It is also the first cause for individual health care cost. Multiple risk factors are mentioned for its development among which elevated uric acid is recently introduced as an inflammatory factor. This study was performed for evaluating the serum uric acid level and severity of CAD determined...
متن کاملNew enzymatic method for serum uric acid at 500 nm.
We describe a manual method, well suited to mechanization, for quantitating serum uric acid at 500 nm. In the assay mixture (0.10 ml of sample and 3.00 ml of reagent) the hydrogen peroxide produced from uric acid by uricase is coupled with p-hydroxybenzoate and 4-aminoantipyrine in the presence of peroxidase to form a colored complex, which is measured. A separate sample blank is obviated by ta...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 16 3 شماره
صفحات -
تاریخ انتشار 1970