Doppler evaluation of homograft valved conduits in children.
نویسندگان
چکیده
To assess the flow characteristics of homograft valved conduits in the immediate postoperative period, 69 children with 71 homograft conduits underwent 2-dimensional and Doppler echocardiographic examination at 1 to 40 days (mean 8) after surgery. Of the 71 conduits studied, 19 were aortic and 52 were pulmonary homograft valved conduits. Two aortic homograft valved conduits were inserted in the aortic position, whereas all remaining homografts were placed in the pulmonary position. On the immediate postoperative echocardiogram, 25 (35%) of the conduit valves had no regurgitation and 44 (62%) had 1+ (mild) regurgitation. Two pulmonary valved conduits (3%) in the pulmonary position had 2+ (moderate) regurgitation and right ventricular dimensions greater than 95% for body surface area. The peak velocity across the homograft valve was normal (less than 1.3 m/s) in 58 valves (82%). In the remaining 13 valves, peak velocity ranged from 1.4 to 2.6 m/s. No homograft valve had a peak velocity greater than 2.6 m/s in the immediate postoperative period. To assess the fate of homograft valved conduits in the intermediate-term follow-up period, 38 children with 38 conduits had a repeat echocardiogram at 6 to 25 months (mean 15 +/- 6) after surgery. Of the 38 conduits examined, 10 (26%) had no regurgitation, 25 (66%) had 1+ regurgitation and 3 (8%) had 2+ regurgitation. Progression of the amount of regurgitation occurred in 11 (29%) patients. At the follow-up examination, peak velocity was less than or equal to 1.4 m/s across 34 conduit valves, between 1.4 and 2.6 m/s across 3 valves and greater than 2.6 m/s across 1 valve.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Homograft valved right ventricle to pulmonary artery conduit as a modification of the Norwood procedure.
BACKGROUND The use of a right ventricle to pulmonary artery (RV-PA) conduit in the Norwood procedure has been proposed to increase postoperative hemodynamic stability. A valve within the conduit should further decrease RV volume load. We report our clinical experience with this modification. METHODS AND RESULTS From February 2002 through August 2005, we performed 88 consecutive Norwood proced...
متن کاملEvaluation of valved saphenous vein homograft as right ventricle-pulmonary artery conduit in modified stage I Norwood operation.
Potential drawbacks from right ventricle-pulmonary artery (RV-PA) conduit in modified Norwood procedure may be regurgitation through the conduit and incision at the systemic ventricle. In order to address the question if valved RV-PA conduit can provide hemodynamic advantages, we retrospectively reviewed the data of patients who underwent modified stage I Norwood operation with either a non-val...
متن کاملOversizing pulmonary homograft conduits does not significantly decrease allograft failure in children.
OBJECTIVE Placement of oversized pulmonary ventricle-pulmonary artery conduits is routinely performed to decrease conduit failure in children. However, this practice has recently been challenged as somatic outgrowth may not be the main determinant of allograft failure in children. Our objective was to determine whether placement of oversized homografts for extracardiac pulmonary ventricle (PV) ...
متن کاملBioprosthetic replacement of the ascending thoracic aorta: what are the options?
Increasing patient age and improved durability of latest generation bioprostheses have stimulated the use of bioprosthetic devices in the setting of ascending aortic replacement as an alternative to mechanical valved conduits or aortic valve-sparing procedures. We performed an English literature review to assess different surgical options that have been described for bioprosthetic replacement o...
متن کاملLong-term follow-up of patients with extracardiac valved conduits.
Seventeen patients having extracardiac valved conduits placed between the right ventricle and pulmonary artery were followed for 7 to 87 months postoperatively (mean, 42 months), at the Heart Institute, Kenritsu Amagasaki Hospital, Japan. There were no late deaths in the study group. Three conduits have been replaced, all because of conduit stenosis. In two-dimensional echocardiographic examina...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The American journal of cardiology
دوره 64 5 شماره
صفحات -
تاریخ انتشار 1989