Purpose. For a precise fit of multiple implant framework, having an accurate definitive cast is imperative. The present study evaluated dimensional accuracy of master casts obtained using different impression trays and materials with open tray impression technique. Materials and Methods. A machined aluminum reference model with four parallel implant analogues was fabricated. Forty implant level impressions were made. Eight groups (n = 5) were tested using impression materials (polyether and vinylsiloxanether) and four types of impression trays, two being custom (self-cure acrylic and light cure acrylic) and two being stock (plastic and metal). The interimplant distances were measured on master casts using a coordinate measuring machine. The collected data was compared with a standard reference model and was statistically analyzed using two-way ANOVA. Results. Statistically significant difference (p < 0.05) was found between the two impression materials. However, the difference seen was small (36 μm) irrespective of the tray type used. No significant difference (p > 0.05) was observed between varied stock and custom trays. Conclusions. The polyether impression material proved to be more accurate than vinylsiloxanether impression material. The rigid nonperforated stock trays, both plastic and metal, could be an alternative for custom trays for multi-implant impressions when used with medium viscosity impression materials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تعیین دقت ثبت ایمپلنت در دو روش تری باز و تری بسته و تعیین ثبت جزئیات سطح دندان حین این قالب‌گیری

Background and Aims: Accurate recording of implant location is required to achieve passive fit and have the implants without stress concentration. The aim of this in-vitro study was to evaluate the dimensional and angular accuracy of open-tray and closed-tray impression techniques using polyether impression material and also to assess the surface detail reproduction of the tooth while impressio...

متن کامل

In Vitro Effect of Vent Size and Spacer Thickness on Pressure Produced during Maxillary Edentulous Impression Making by Different Impression Materials

Background and Aim: Inappropriate transfer of pressure during final impression making in fabrication of complete denture can result in ridge resorption. This study aimed to assess the effect of vent size and spacer thickness on pressure produced during maxillary edentulous impression making by different impression materials in vitro. Materials and Methods: This experimental study was carried...

متن کامل

Comparison of implant cast accuracy of multiple implant impression technique with different splinting materials: An in vitro study

INTRODUCTION An accurate and passive fit of implant framework prosthesis, as well as the successful surgical operation is suggested as one of the critical requirements for long-term implant success. OBJECTIVE The purpose of this in vitro study was to evaluate the accuracy of the master cast using open tray impression technique with conventional and novel splinting materials. METHODOLOGY A m...

متن کامل

Comparative Analysis of Dimensional Accuracy of Two Types of Silicone Impression Materials: Optosil and Elite-HD

Statement of the Problem: Understanding about impression materials, their properties, uses and manipulation can guide operators towards having more successful restorations. Purpose: The aim of this in vitro study was to compare the accuracy of a condensation silicone impression material, Optosil, and an addition poly siloxane impression material, Elite-HD. Materials and Method: A laboratory mod...

متن کامل

Dimensional Accuracy of Polyvinyl Siloxane Impression Materials Considering Impression Techniques– A Literature Review

Objectives Impression accuracy is the main determinant of the fit, form and function of prosthetic restorations. Polyvinyl siloxane (PVS) is the material of choice in most clinical situations. The purpose of this paper is to provide an up-to-date review of scientific articles which discuss the dimensional accuracy of PVS impression material using various impression techniques, tray types and sp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2017  شماره 

صفحات  -

تاریخ انتشار 2017