Determination of (ultra)trace amounts of arsenic(III) and arsenic(V) in water by inductively coupled plasma mass spectrometry coupled with flow injection on-line sorption preconcentration and separation in a knotted reactor.
نویسندگان
چکیده
A method has been developed for determination of (ultra)trace amounts of As(III) and As(V) in water by flow injection on-line sorption preconcentration and separation coupled with inductively coupled plasma mass spectrometry (ICPMS) using a knotted reactor (KR). The determination of As(III) was achieved by selective formation of the As(III)-pyrrolidine dithiocarbamate complex over a sample acidity range of 0.01-0.7 mol L-1 HNO3, its adsorption onto the inner walls of the KR made from 150-cm-long, 0.5-mm-i.d. PTFE tubing, elution with 1 mol L-1 HNO3, and detection by ICPMS. Total inorganic arsenic was determined after prereduction of As(V) to As(III) in a 1% (m/v) L-cysteine-0.03 mol L-1 HNO3 media. The concentration of As(V) was calculated by difference (the total inorganic arsenic and As(III)). Owing to the group-specific character of the chelating agent, and the use of an efficient rinsing step before elution, the interferences encountered in conventional ICPMS from common major matrix, alkali and alkaline earth metals, and chlorides were eliminated. The presence of organoarsenic species such as monomethylarsonate and dimethylarsinate in water samples had no effect on the results of As(III) and As(V). Thus, the method can be applied to the speciation analysis of inorganic arsenic at submicrogram per liter levels in aqueous solutions with high total content of dissolved solid and/or high content of chlorides. Using a preconcentration time of 60 s and a sample flow rate of 5 mL min-1, an enhancement factor of 22 was achieved in comparison with conventional ICPMS. The time required for a single determination was 200 s. The detection limits (3s) was evaluated to be 0.021 microgram L-1 for As(III) and 0.029 microgram L-1 for total inorganic arsenic. The precision for 14 replicate determinations of 1 microgram L-1 As(III) was 2.8% (RSD) with drift correction and 3.9% (RSD) without drift correction. The concentrations of As(III) and As(V) in synthetic mixtures obtained by the present method were in good agreement with expected values. Results obtained by the proposed method for total arsenic in a river water reference material agreed well with certified and recently reevaluated values. The method was also applied to the speciation analysis of inorganic arsenic in porewaters.
منابع مشابه
Selective Separation and Preconcentration of trace Amounts of Gallium in Water and Rice Samples using Cloud Point Extraction and Determination by Inductively Coupled Plasma-Atomic Emission Spectrometry
In the present study a cloud-point extraction process using non-ionic surfactant Triton X-114 for selective extraction of gallium from aqueous solutions was developed. The method is based on the complex formation of Ga (III) with N, N′ -bis (salycilidene)-1, 2-phenylenediamine (salophen) as a chelating agent in buffer media of pH 5. After phase separation and dilution of the surfactant-rich pha...
متن کاملFlow injection on-line sorption preconcentration coupled with hydride generation atomic fluorescence spectrometry for determination of (ultra)trace amounts of arsenic(III) and arsenic(V) in natural water samples.
A flow injection on-line sorption preconcentration and separation in a knotted reactor (KR) was coupled to hydride generation atomic fluorescence spectrometry (HG-AFS) for speciation of inorganic arsenic in natural water samples. The method involved on-line formation of the As(III)-pyrrolidinedithiocarbamate (PDC) complex over a sample acidity of 0.001-0.1 mol L(-1) HCl, its adsorption onto the...
متن کاملDirect Determination of Total Arsenic and Arsenic Species by Ion Chromatography Coupled with Inductively Coupled Plasma Mass Spectrometry
The simultaneous determination of As(III), As(V), and DMA has been performed by ion chromatography (IC) coupled with inductively coupled plasma-mass spectrometry (ICP-MS). The separation of the three arsenic species was achieved by an anionic separator column (AS 7) with an isocratic elution system. The separated species were directly detected by ICP-MS as an element-selective detection method....
متن کاملMulti-element analysis of saline matrices by inductively coupled plasma mass spectrometry following on-line preconcentration using a knotted reactor.
A versatile preconcentration system for trace element determination by ICPMS was developed. It is composed of a commercial flow injection analysis system (FIAS) retrofitted with a home-made control unit containing three solenoid valves and working concomitantly with the FIAS, permitting selection and segmentation of sample, reagent, washing solution and elution flow. The knotted reactor used ha...
متن کاملReview of preconcentration and solid phase extraction for the determination of trace Lead
Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical chemistry
دوره 70 22 شماره