Use of respiratory impedance in prehospital care of hypotensive patients associated with hemorrhage and trauma: a case series.

نویسندگان

  • Victor A Convertino
  • Brent Parquette
  • John Zeihr
  • Kevin Traynor
  • Daryn Baia
  • Mark Baumblatt
  • Levon Vartanian
  • Mithun Suresh
  • Anja Metzger
  • Robert T Gerhardt
  • Keith G Lurie
  • David Lindstrom
چکیده

BACKGROUND The respiratory pump can be optimized to enhance circulation in patients with hypotension by having patients spontaneously breathe through a low level of inspiratory resistance. This can be achieved with an impedance threshold device (ITD) designed to provide 7 cm H2O resistance during spontaneous inspiration with minimal resistance during expiration. Little is known about the effects of harnessing this physiological concept to increase blood pressure (BP) in the prehospital setting of care for patients with hypotension caused by blood loss or trauma. In this case series, we report on the feasibility, effectiveness, and safety of rapidly deploying the ITD by first responders to treat hypotension secondary to blood loss and trauma in the urban setting by emergency medical services personnel. METHODS Hemodynamic data from hypotensive patients (pretreatment systolic BP [SBP] <100 mm Hg) from 3 U.S. cities where the ITD is deployed were evaluated. The primary end point was maximum change in SBP and diastolic BP (DBP) from before to during ITD use in patients with hypotension secondary to documented blood loss or trauma. Secondary end points were device tolerance, whether the patient felt "better," change in heart rate, O2 saturation, and adverse events. RESULTS Of the 255 hypotensive patients treated, there were 26 categorized with blood loss and 13 with trauma. In this 39-patient subgroup, the SBP and DBP (mean ± SD) increased from 79 ± 14 mm Hg and 48 ± 12 mm Hg before ITD placement to 110 ± 17 mm Hg and 66 ± 14 mm Hg after ITD placement (p < 0.001). Breathing through the ITD resulted in no reported adverse events, was well tolerated, and resulted in feeling "better" in more than 85% of the patients. CONCLUSION Use of an ITD by emergency medical services personnel on hypotensive spontaneously breathing patients secondary to blood loss and trauma increased SBP and DBP and was feasible, well tolerated, and not associated with adverse effects (e.g., increased bleeding).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Satisfaction with the performance of emergency medical services: a case study in Tabriz

Objective: Assessing patients’ satisfaction with emergency medical services (EMSs) is an important managerial point of view. The present study aimed to assess the patients’ satisfaction with EMS in Tabriz, Iran.Methods: This is a descriptive-analytic study that was done in the prehospital emergency and disaster management center of Tabriz University of Medical Sciences. In this study, fro...

متن کامل

Prehospital Trauma Management: Evaluation of a New Designed Smartphone Application

Background: Regarding the undeniable role of nurses in caring for patients with trauma, a suitable method is required for the education of nursing students to meet their needs. In this study, first we designed an educational smartphone application for pre-hospital trauma management and then nursing students evaluated its usefulness.  Methods: This applied study has a cross-sectional design and...

متن کامل

Effect of cervical collars on intracranial pressure in patients with head neurotrauma

Trauma patients are at high risk of cervical and associated injuries. The standard protocol includes immobilization of the cervical spine in a polytrauma as it will help to prevent spinal injuries in the prehospital settings. Hard cervical collar (or alternatives) is routinely used until the cervical spine clearance is obtained . In patients with traumatic brain injury avoiding any kind of mane...

متن کامل

Low-cost improvements in prehospital trauma care in a Latin American city.

OBJECTIVE Prehospital care is a critical component of efforts to lower trauma mortality. In less-developed countries, scarce resources dictate that any improvements in prehospital care must be low in cost. In one Latin American city, recent efforts to improve prehospital care have included an increase in the number of sites of ambulance dispatch from two to four and introduction of the Prehospi...

متن کامل

Use of an impedance threshold device in spontaneously breathing patients with hypotension secondary to trauma: an observational cohort feasibility study.

BACKGROUND An impedance threshold device (ITD) intended for use in the spontaneously breathing patient has been shown to raise blood pressure in hypotensive patients. This device has not been evaluated in patients with hypotension secondary to trauma. This study focused on changes in key vital signs when the ITD was added to the paramedic treatment protocol for hypotensive patients with prehosp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The journal of trauma and acute care surgery

دوره 73 2 Suppl 1  شماره 

صفحات  -