Evaluation of Virtual Touch Tissue Imaging Quantification, a New Shear Wave Velocity Imaging Method, for Breast Lesion Assessment by Ultrasound

نویسندگان

  • Michael Golatta
  • Mirjam Schweitzer-Martin
  • Aba Harcos
  • Sarah Schott
  • Christina Gomez
  • Anne Stieber
  • Geraldine Rauch
  • Christoph Domschke
  • Joachim Rom
  • Florian Schütz
  • Christof Sohn
  • Jörg Heil
چکیده

OBJECTIVES To evaluate virtual touch tissue imaging quantification (VTIQ) as a new elastography method concerning its intra- and interexaminer reliability and its ability to differentiate benign from malignant breast lesions in comparison to and in combination with ultrasound (US) B-mode breast imaging reporting and data system (BI-RADS) assessment. MATERIALS AND METHODS US and VTIQ were performed by two examiners in 103 women with 104 lesions. Intra- and interexaminer reliability of VTIQ was assessed. The area under the receiver operating curve (AUC), sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of BIRADS, VTIQ, and combined data were compared. RESULTS Fifty-four of 104 lesions were malignant. Intraexaminer reliability was consistent, and interexaminer agreement showed a strong positive correlation (r = 0.93). The mean VTIQ values in malignant lesions were significantly higher than those in benign (7.73 m/s ± 1.02 versus 4.46 m/s ± 1.87; P < 0.0001). The combination of US-BIRADS with the optimal cut-off for clinical decision making of 5.18 m/s yielded a sensitivity of 98%, specificity of 82%, PPV of 86%, and NPV of 98%. The combination of BIRADS and VTIQ led to improved test validity. CONCLUSION VTIQ is highly reliable and reproducible. There is a significant difference regarding the mean maximum velocity of benign and malignant lesions. Adding VTIQ to BIRADS assessment improves the specificity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Association of conventional ultrasound, elastography and clinicopathological factors with axillary lymph node status in invasive ductal breast carcinoma with sizes > 10 mm

Background To evaluate whether conventional ultrasound, elastography [conventional strain elastography of elasticity imaging, acoustic radiation force impulse induced strain elastography of virtual touch tissue imaging, and a novel two-dimensional shear wave elastography of virtual touch tissue imaging quantification] and clinicopathological factors are associated with axillary lymph node metas...

متن کامل

Virtual Touch Tissue Imaging Quantification Shear Wave Elastography: Prospective Assessment of Cervical Lymph Nodes.

The goal of this study was to prospectively evaluate the diagnostic performance of Virtual Touch tissue imaging quantification (VTIQ) shear wave elastography in the discrimination of benign and malignant cervical lymph nodes in routine clinical practice. Shear wave velocity was analyzed using VTIQ in 100 patients with 100 histologically proven cervical lymph nodes. Diagnostic performance was ev...

متن کامل

A novel two-dimensional quantitative shear wave elastography for differentiating malignant from benign breast lesions.

OBJECTIVE The purpose of this study was to evaluate the diagnostic performance of a novel quantitative shear wave elastography (SWE) of virtual touch tissue imaging quantification (VTIQ) in diagnosis of breast lesions. METHODS The conventional ultrasound (US) and VTIQ images of 133 pathologically proven breast lesions in 98 patients were assessed. The breast lesions were classified by US brea...

متن کامل

Diagnostic value of virtual touch tissue imaging quantification for benign and malignant breast lesions with different sizes.

The study was to explore diagnostic value of the virtual touch tissue imaging quantification (VTIQ) in distinguishing benign and malignant breast lesions of variable sizes. We performed conventional ultrasound and VTIQ in 139 breast lesions. The lesions were categorized into three groups according to size (group 1, ≤ 10 mm; group 2, 10-20 mm; and group 3, > 20 mm), and their mean, min, and max ...

متن کامل

Diagnostic Value of Virtual Touch Tissue Quantification for Breast Lesions with Different Size

PURPOSE To evaluate diagnostic value of the virtual touch tissue quantification (VTTQ) for breast lesions with different sizes. MATERIALS AND METHODS Patients with 206 breast lesions were categorized into three groups according to lesion size (<10 mm, 10-20 mm, and >20 mm). Breast lesions were examined by conventional ultrasound and VTTQ, and shear wave velocity (SWV) of each lesion and adjac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2014  شماره 

صفحات  -

تاریخ انتشار 2014