Simultaneous monitoring of inorganic cations, amines and amino acids in human sweat by capillary electrophoresis.
نویسندگان
چکیده
The determination of cationic constituents of sweat is widely recognized as a difficult analytical task due to its complex composition and minute sample volumes available for the individual analysis. Capillary electrophoresis (CE) has been evaluated as a simple routine method to measure sweat metal cations, biogenic amines, and amino acids using a sampling procedure previously developed in one of collaborative teams. The carrier electrolyte, which consisted of 10 mM 4-methylbenzylamine, 6.5 mM alpha-hydroxyisobutyric acid, and 2 mM 18-crown-6 at pH 4.25, allowed the separation of five cations (NH(4)(+), K(+), Ca(2+), Na(+), Mg(2+)) and four amino acids (ornithine, histidine, lysine, arginine) to be completed in about 13 min with a positive polarity of the applied voltage (30 kV). By increasing the sample volume (due to employing hydrodynamic instead of hydrostatic injection mode), it was also possible to detect indirect UV signals of Zn(2+), diethanolamine, and trithanolamine. Sweat samples were collected from the fingers and forearms of three healthy male volunteers and analyzed by CE. A good repeatability and reproducibility of peak area responses based on five intraday and three inter-day assays (average %R.S.D. less than 3.5 and 2.5, respectively) were obtained. The limits of detection were in the range of 3.2-5.8 microM for alkali and alkaline-earth cations (hydrostatic injection) and 0.27-0.79 microM for other target analytes (hydrodynamic injection). The analytical results for particular analytes were found to vary, depending on the sampling spot and individual, but in general correspond well to clinical concentration ranges.
منابع مشابه
Recent advances in the application of capillary electromigration methods for food analysis.
This review covers the application of capillary electromigration methods to analyze foods and food components, including amino acids, biogenic amines, peptides, proteins, DNAs, carbohydrates, phenols, polyphenols, pigments, toxins, pesticides, vitamins, additives, small organic and inorganic ions, chiral compounds, and other compounds in foods, as well as those applications of CE for monitoring...
متن کاملCapillary electrochromatography with contactless conductivity detection for the determination of some inorganic and organic cations using monolithic octadecylsilica columns.
A fast separation of alkali and alkaline earth metal cations and ammonium was carried out by capillary electrochromatography on monolithic octadecylsilica columns of 15 cm length and 100 microm inner diameter using water/methanol mixtures containing acetic acid as mobile phase. On-column contactless conductivity detection was used for quantification of these non-UV-absorbing species. The method...
متن کاملRecent advances in the application of capillary electromigration methods for food analysis and Foodomics.
This review work presents and discusses the main applications of capillary electromigration methods in food analysis and Foodomics. Papers that were published during the period February 2013-February 2015 are included following the previous review by Garcia-Cañas et al. (Electrophoresis, 2014, 35, 147-169). Analysis by CE of a large variety of food-related molecules with different chemical prop...
متن کاملSimultaneous light emitting diode-induced fluorescence and contactless conductivity detection for capillary electrophoresis.
A combined detection system of simultaneous contactless conductometric and fluorescent detection for capillary electrophoresis (CE) has been designed and evaluated. The two processes share a common detection cell. A blue light-emitting diode (LED) was used as the excitation source and an optical fiber was used to collect the emitting fluorescence for fluorescent detection (FD). Inorganic ions, ...
متن کاملSimultaneous Determination of Inorganic Ions in Post-Blast Residues using Capillary Electrophoresis
Capillary electrophoresis method for simultaneous determination of inorganic anions and cations was developed using 2,6-pyridinedicarboxylic acid (PDC) as a background electrolyte (BGE) with indirect UV detection. In order to detect both anions and cations simultaneously, the electromagnetic flow was reversed by the addition of cetryltrimethylammonium hydroxide (CTAH). The parameters which infl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytica chimica acta
دوره 581 1 شماره
صفحات -
تاریخ انتشار 2007