The Effect of Airway Pressure Release Ventilation on Pulmonary Catheter Readings: Specifically Pulmonary Capillary Wedge Pressure in a Swine Model

نویسندگان

  • Ahmad M. Slim
  • Shaun Martinho
  • Jennifer Slim
  • Eddie Davenport
  • Luadino M. Castillo-Rojas
  • Eric A. Shry
چکیده

Background. Airway pressure release ventilation (APRV) is a mode of mechanical ventilation that theoretically believed to improve cardiac output by lowering right atrial pressure. However, hemodynamic parameters have never been formally assessed. Methods. Seven healthy swine were intubated and sedated. A baseline assessment of conventional ventilation (assist control) and positive end-expiratory pressure (PEEP) of 5 cm H(2)O was initiated. Ventilator mode was changed to APRV with incremental elevations of CPAP-high from 10 to 35 cm H(2)O. After a 3-to-5-minute stabilization period, measurements of hemodynamic parameters (PCWP, LAP, and CVP) were recorded at each level of APRV pressure settings. Results. Increasing CPAP caused increased PCWP and LAP measurements above their baseline values. Mean PCWP and LAP were linearly related (LAP = 0.66(∗)PCWP + 4.5 cm H(2)O, R(2) = 0.674, and P < .001) over a wide range of high and low CPAP values during APRV. With return to conventional ventilation, PCWP and LAP returned to their baseline values. Conclusion. PCWP is an accurate measurement of LAP during APRV over variable levels of CPAP. However, PCWP and LAP may not be accurate measurements of volume when CPAP is utilized.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ventricular Tachycardia and the Chest Thump

CHEST, 74: 6, DECEMBER, 1978 pulmonary capillary wedge pressure to normal by increasing extramural pressure. So for us, therapy with IPPV and PEEP usually influences the pulmonary capillary wedge pressure, especially when the central blood volume varies from normal; thus, the interest and limits of the “weaning test” are clearly defined. In some cases, therapy with artificial ventilation does n...

متن کامل

Ventricular tachycardia and the chest thump.

CHEST, 74: 6, DECEMBER, 1978 pulmonary capillary wedge pressure to normal by increasing extramural pressure. So for us, therapy with IPPV and PEEP usually influences the pulmonary capillary wedge pressure, especially when the central blood volume varies from normal; thus, the interest and limits of the “weaning test” are clearly defined. In some cases, therapy with artificial ventilation does n...

متن کامل

Sustained Hypoxic Pulmonary Vasoconstriction in the Isolated Perfused Rat Lung: Effect of α1-adrenergic Receptor Agonist

Background: Alveolar hypoxia induces monophasic pulmonary vasoconstriction in vivo, biphasic vasoconstriction in the isolated pulmonary artery, and controversial responses in the isolated perfused lung. Pulmonary vascular responses to sustained alveolar hypoxia have not been addressed in the isolated perfused rat lung. In this study, we investigated the effect of sustained hypoxic ventilation o...

متن کامل

“Expiratory holding” approach in measuring end-expiratory pulmonary artery wedge pressure for mechanically ventilated patients

OBJECTIVE To accurately measure the end-expiratory pulmonary artery wedge pressure (PAWP) with the "expiration holding" function on the ventilator and the "pulmonary artery wedge pressure review" software on the monitor. MATERIALS AND METHODS Fifty prospective measurements were made on 12 patients undergoing pulmonary artery catheter and mechanical ventilation. All measurements were divided i...

متن کامل

Influence of catheter tip position on pulmonary wedge pressures.

• Simultaneously recorded left atrial and pulmonary artery wedge pressures demonstrate that the left atrial pressure pulse can be transmitted across the pulmonary capillary bed and recorded by the wedged catheter." However, such satisfactory wedge tracings are not always obtainable, and in many trials the tracing is featureless, damped or distorted by artifacts and obviously is not a true refle...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2011  شماره 

صفحات  -

تاریخ انتشار 2011