Improving the Resolution in Direct Inductive Sensor-to-Microcontroller Interface

نویسندگان

  • Zivko Kokolanski
  • Ferran Reverter
  • Cvetan Gavrovski
  • Vladimir Dimcev
چکیده

The paper describes an improved direct inductive sensor to microcontroller interface by incorporating external MOSFET transistors. In such a way, the measured discharging time interval can be increased (through the discharging time constant) which results in increased resolution for a given time base. The experimental results show that the resolution of the measurements can be significantly improved in comparison to the basic low pass filter and high pass filter topology. Moreover, such circuit can be used to interface inductive sensors with lower inductance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving the Single Point Calibration Technique in Direct Sensor-to-Microcontroller Interface

Abstrac t An improved single point calibration technique applied on direct sensor-to-microcontroller interface is presented. The improvements are in reducing the systematic errors in a given measurement range by increasing the transfer characteristics nonlinearity. The experimental results showed that this approach reduces the overall systematic errors of the measurements more than twice and co...

متن کامل

Microcontroller-based interface circuit for inductive sensors

This work proposes a fully-digital interface circuit for the measurement of inductive sensors using a low-cost microcontroller (μC) and without any intermediate active circuit. Apart from the μC and the sensor, the circuit just requires an external resistor and a reference inductance so that two RL circuits with a high-pass filter (HPF) topology are formed. The μC appropriately excites such RL ...

متن کامل

The Effects of Excitation Signal on the Resolution of the Liquid Crystal Capacitive Chemical and Biological Sensors

In this paper excitation characteristics of the Liquid Crystal (LC) capacitive chemical and biological sensor are examined and the optimum frequency and voltage range for the sensor interface are introduced. Interdigitated capacitor has been used for the sensor capacitance measurement and two different molecular orientations, homeotropic and homogenous, have been considered. The LC sensor capac...

متن کامل

An Intelligent Computer Interface Utilizing Parallel Picocontrollers (TECHNICAL NOTE)

The design of an interface unit is described, in which RS232 serial data is converted to latched parallel data on 22 independent lines. The data direction of each line is programmable through the serial port. Two picocontrollers are employed in a parallel processing mode to give the required number of I/O pins, and data on the shared serial line is coded to separate data streams to the individu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015