Electrical impedance tomography : from topology

نویسندگان

  • Michael Hintermüller
  • Antoine Laurain
  • M. HINTERMÜLLER
  • A. LAURAIN
چکیده

Abstract: A level set based shape and topology optimization approach to electrical impedance tomography (EIT) problems with piecewise constant conductivities is introduced. The proposed solution algorithm is initialized by using topological sensitivity analysis. Then it relies on the notion of shape derivatives to update the shape of the domains where conductivity takes different values.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrical Impedance Tomography: from Topology to Shape

A level set based shape and topology optimization approach to electrical impedance tomography (EIT) problems with piecewise constant conductivities is introduced. The proposed solution algorithm is initialized by using topological sensitivity analysis. Then it relies on the notion of shape derivatives to update the shape of the domains where the conductivity takes its different values.

متن کامل

Electrical Impedance Tomography: Topology Optimization

The Electrical Impedance Tomography (EIT) is a study of body parts who use electric current. Is studied through computers resistance or conductivity of these parts, producing an image used for medical diagnosis. A body is wrapped in a blanket placed with small electrodes and receivers of electric current, potential difference. Based on data obtained from a series of measurements at the electrod...

متن کامل

Topology Optimization Method Applied to Obtain Images from Electrical Impedance Tomography Technique

The Electrical Impedance Tomography (EIT) is a recent monitoring technique of biological tissues that allows us to obtain images of a transversal plane in any section of human body. The images are generated from voltage values measured around the plane section of human body. These voltages are obtained by applying an alternated sequence of low amplitude electrical currents in according to an ex...

متن کامل

Applications of Electrical Impedance Tomography in Neurology

Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...

متن کامل

Topology Optimization Applied to Electrical Impedance Tomography

Abstract Electrical Impedance Tomography (EIT) is a imaging method that estimates conductivity distribution inside a body (domain). In this method, images are obtained by applying a sequence of low intensity electrical currents, through electrodes positioned around the body. Applications of EIT can be often found in geophysics sciences, non-destructive testing and medical applications. Although...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009