In vivo validation of an experimental adaptive quantitative coronary angiography algorithm to circumvent overestimation of small luminal diameters.

نویسندگان

  • D Keane
  • E Gronenschild
  • C Slager
  • Y Ozaki
  • J Haase
  • P W Serruys
چکیده

The reliability of quantitative coronary angiography (QCA) measurements is of fundamental importance for the study and practice of interventional cardiology. In vivo validation results have consistently reported a tendency for QCA systems to overestimate small luminal diameters. Such a systematic error may result in the underestimation of luminal gain during intracoronary procedures and in the underestimation of progression of coronary artery disease during longitudinal studies. We report the in vivo validation results of an experimental adaptive edge-detection algorithm that was developed to reduce overestimation of small luminal diameters by incorporating a dynamic function of variable kernel size of the derivative operator and variable weighting of the first and second derivatives of the brightness profile. The results of the experimental algorithm were compared to those of the conventional parent edge detection algorithm with fixed parameters. Dynamic adjustment of the edge-detection algorithm parameters was found to improve measurements of small (< 0.8-mm) luminal diameters as evidenced by an intercept of +.07 mm for the algorithm with variable weighting compared to +0.21 mm for the parent algorithm with fixed weighting. A slope of < 1 was found for both the parent and experimental algorithms with subsequent underestimation of large luminal diameters. Systematic errors in a QCA system can be identified and corrected by the execution of objective in vivo validation studies and the consequent refinement of edge-detection algorithms. The overestimation of small luminal diameters may be overcome by the incorporation of a dynamic edge-detection algorithm.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative validation of quantitative coronary angiography systems. Results and implications from a multicenter study using a standardized approach.

BACKGROUND Computerized quantitative coronary angiography (QCA) has fundamentally altered our approach to the assessment of coronary interventional techniques and strategies aimed at the prevention of recurrence and progression of stenosis. It is essential, therefore, that the performance of QCA systems, upon which much of our scientific understanding has become integrally dependent, is evaluat...

متن کامل

Quantification of absolute luminal diameter by computer-analyzed digital subtraction angiography: an assessment in human coronary arteries.

Determination of absolute lumen diameters has been shown to be useful in predicting the functional importance of a coronary stenosis. In this study, both single-plane and orthogonal biplane digital subtraction angiograms were obtained in human cadaver coronary arteries. A single absolute diameter was calculated at the site of greatest narrowing in 20 segments by two automated computerized algor...

متن کامل

Quantitative angiographic morphology of coronary stenoses leading to myocardial infarction or unstable angina.

Identification of a characteristic morphology of a coronary stenosis likely to result in myocardial infarction would facilitate the prospective evaluation of infarct prevention strategies and identification of high-risk patients. We postulated that coronary lesions associated with recent myocardial infarction or unstable angina would have an angiographic morphology suggesting disruption of an a...

متن کامل

Comparison of Video & Verbal Education on Satisfaction and Post Operative Complications of Patients Undergoing Coronary Angiography

Background & Objectives: Coronary angiography is one of definitive diagnostic tests for coronary artery disease. Patients' education is one of the most interventions before coronary Angiography. The objective of this study is to compare two patients' education method (Video & Verbal) on patients' satisfaction and complications after coronary angiography. Materials & Methods: In a quasi-experime...

متن کامل

Effects of Cilostazol on the Drug-Eluting Stent in Native Coronary Arteries

Background and Objectives:Cilostazol is an antiplatelet drug with antiproliferative properties when administered after coronary bare metal stent implantation. However, its effect on clinical and angiographic outcomes after sirolimus-eluting stent (SES) implantation in native coronary arteries has not been established. Subjects and Methods:Two hundred patients who had undergone successful SES im...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Catheterization and cardiovascular diagnosis

دوره 36 1  شماره 

صفحات  -

تاریخ انتشار 1995