Clinical evaluation of bionime rightest GM310 biosensors with a simplified electrode fabrication for alternative-site blood glucose tests.

نویسندگان

  • Ming-Hsun Wu
  • Mei-Yen Fang
  • Lin-Ni Jen
  • Hung-Chan Hsiao
  • Andreas Müller
  • Cheng-Teng Hsu
چکیده

BACKGROUND Most processes for fabricating biosensors applied to screen-printed carbon electrodes (SPCEs) are complex. This study presents a novel one-step process for manufacturing electrodes for injection-molding biosensors. METHODS During the sensor-fabrication process, barrel-plated gold electrodes were inserted into an injection-molded base. The electrode directly touched the electrical contact of a meter. We analyzed technical measurements for this biosensor, including tests of the measurement range, within-run imprecision, and between-meter imprecision. In clinical trials, experienced technicians tested 3 alternative sites (fingertip, palm, and arm). The results were simultaneously compared with plasma values obtained with the hexokinase method on the Olympus AU640 instrument. Analytical results were evaluated according to International Standards Organization 15197 (ISO 15197:2003) criteria and by Clarke error grid analysis (EGA), and CVs were calculated to evaluate within-run imprecision. RESULTS The glucose measurement range was 0.6- 33.3 mmol/L (y = 0.96x + 0.07 mmol/L; r(2) = 0.9977). The CVs in the within-run imprecision test were 1.7%-3.5%, and the overall CV was 2.1%, indicating good reproducibility of results. The Student t-tests of mean values from 5 meters revealed statistically insignificant differences (P > 0.05). In clinical trials, the agreement of the Rightest GM310 meter results with those of a laboratory method complied with ISO 15197:2003 criteria. In the EGA, 100% of the values were within the acceptable zones (A + B), and the proportion of values within zone A exceeded 95%. CONCLUSIONS The Bionime Rightest GM310 meter applied a simplified process for biosensor fabrication and displayed acceptable performance for monitoring glucose concentrations at alternative test sites.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correction: Yoo, E.H., et al. Glucose Biosensors: An Overview of Use in Clinical Practice. Sensors 2010, 10, 4558–4576

Manufacturer Brand Assay method Minimal sample volume (uL) Test time (second) Assay range (mg/dL) Hematocrit range (%) Memory (results) Abbott FreeStyle Freedom Lite GDH-PQQ 0.3 ~5 20~500 15~65 400 AgaMatrix WaveSense KeyNote GOD 0.5 4 20~600 20~60 300 Arkray Glucocard X-meter GDH 0.3 5 10~600 30~52 360 Bayer Ascensia Contour GDH-FAD 0.6 5 10~600 0~70 480 Bionime Rightest GM300 GOD 1.4 8 20~600...

متن کامل

The obtain optimum production conditions for Glucose Oxidase biosensor using software Qualtek-4

The Glucose Oxidase (Gox) electrochemical sensors were used to detect a little amount of glucose. In this paper, the pure platinum plate (length of 5 cm and a width of 3 mm), the Ag/AgCl electrode and platinum electrode (diameter of 1 mm) were applied as a working electrode (W.E), reference electrode and auxiliary electrode sequential. Factors measured, glucose concentration and pH is Phosphate...

متن کامل

The obtain optimum production conditions for Glucose Oxidase biosensor using software Qualtek-4

The Glucose Oxidase (Gox) electrochemical sensors were used to detect a little amount of glucose. In this paper, the pure platinum plate (length of 5 cm and a width of 3 mm), the Ag/AgCl electrode and platinum electrode (diameter of 1 mm) were applied as a working electrode (W.E), reference electrode and auxiliary electrode sequential. Factors measured, glucose concentration and pH is Phosphate...

متن کامل

Comparison of Two Veterinary Blood Glucose Meters and One Human-Based Glucose Meter for Use in Dogs

Background: Recently, tendency to use veterinary specific Portable blood glucose meter (PBGMs) has increased. However, assessment of their analytical and clinical accuracy is a matter of concern. OBJECTIVES: To assess accuracy of two veterinary (AlphaTRAK2 and CERA-PET) and one human-based (Bionime) PBGMs for canine blood samples. METHODS: In this cross-sectional study, a total of 160 client-ow...

متن کامل

Application of Semipermeable Membranes in Glucose Biosensing

Glucose biosensors have received significant attention in recent years due to the escalating mortality rate of diabetes mellitus. Although there is currently no cure for diabetes mellitus, individuals living with diabetes can lead a normal life by maintaining tight control of their blood glucose levels using glucose biosensors (e.g., glucometers). Current research in the field is focused on the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 54 10  شماره 

صفحات  -

تاریخ انتشار 2008