Investigation of the influence of high humidity and exposure duration on the measurement results of radon concentration by means of PicoRad system in the CLOR calibration chamber

نویسندگان

  • Olga Stawarz
  • Maria Karpińska
  • Kalina Mamont-Ciesla
چکیده

Although radon dose to lungs comes mainly from shortlived radon daughters, most of its estimations for general population is based on the measurements of radon gas concentration instead of radon progeny and acceptance of a constant equilibrium factor between radon and its short-lived decay products. It is so because integrating passive measurements of radon gas concentration are simpler and cheaper, more convenient and practical from the point of view of people who are the subject of radon exposure. The most common passive methods of radon measurements in large-scale surveys are solid-state nuclear alpha track detectors [1] and activated charcoal collectors [4]. While the track detector method is fully integrating over usually a couple of months or longer, the activated charcoal collectors are used over exposure periods of a few days, up to 6 and the mean radon concentration can be obtained as early as 4 h after the end of exposure [9]. Thus, they are applied when the results are required quickly. The short duration of useful exposure of the charcoal canisters arises from the fact that the charcoal is a collector of radon, but not detector, and the half-life of Rn is only Investigation of the influence of high humidity and exposure duration on the measurement results of radon concentration by means of PicoRad system in the CLOR calibration chamber Olga Stawarz, Maria Karpińska, Kalina Mamont-Ciesla

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calibration and optimization of a low cost diffusion chamber for passive separated measurements of radon and thoron in soil by Lexan PC SSNTD

Background: Separate radon and thoron measurements in soil are very important in assessment of internal exposure due to inhalation of such radioactive gases. Materials and Methods: In this study, a low cost, small size, passive diffusion chamber has been developed for simple measurement of Radon-222 and Radon-220(Thoron) gases separately in soil. The diffusion chamber consists of two films and ...

متن کامل

Measurement of Contemporary and Retrospective Radon Concentration in Ramsar Dwellings Using Polycarbonate Detector

The origins of radon gas are the amount of uranium decay in the soil that is released into space and through the interior gaps of  buildings. Radon can enter the respiratory system and cause radiation hazards. Recently research has identified Radon as the second leading cause of lung cancer after cigarette smoking. The indoor concentration of Radon progeny is mentioned as an important issue reg...

متن کامل

Radon concentration and gamma exposure in some Kosovo underground mines

Background: In this study are submitted the radon concentration measurement results of four underground mines: Stanterg, Artana, Hajvali and Badovc, which are owned by Trepça Enterprise, Kosovo. The mines have the same geological formation and from these mines are extracted ores rich with lead, zinc, silver, and gold. The radiation exposures caused by radon and radon daughters was determ...

متن کامل

Indoor radon survey in Shiraz-Iran using developed passive measurement method

Background: While in the open air the amount of radon gas is very small and does not pose a health risk, in confined spaces, radon can accumulate to relatively high levels and become a health hazard. Exposure to high levels of radon has been associated with an increased risk of lung cancer, depending on the time length of exposure. Radon level in dwelling of Shiraz with 1,200,000 popul...

متن کامل

Evaluation of Radon Pollution in Underground Parking Lots by Discomfort Index

Introduction Recent studies of public underground parking lots showed the influence of radon concentration and the probable discomfort caused by parking cars. Materials and Methods Radon concentration was measured in semi-closed public parking lots in the six governorates of Kuwait, using Durridge RAD7radon detector (USA). Results The peak radon concentration in the parking lots of Kuwait gover...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006