Effect of pretreatment prostate volume on urinary quality of life following intensity-modulated radiation therapy for localized prostate cancer
نویسندگان
چکیده
BACKGROUND The aim of this study was to describe the effect of pretreatment prostate volume on urinary quality of life after intensity-modulated radiation therapy (IMRT) for clinically localized prostate cancer. METHODS A total of 368 men treated with prostate IMRT (77.4-81 Gy) were stratified into three gland volume groups, ie, <30 g (group 1), 30-60 g (group 2), and >60 g (group 3). Post-IMRT urinary function was evaluated by National Cancer Institute Common Terminology Criteria for Adverse Events (CTCAE) version 4.0 genitourinary guidelines at one year post-IMRT, and surveyed by the International Prostate Symptom Score (IPSS) before treatment, and then at one month and one year post-IMRT. RESULTS Late (one year post-IMRT) CTCAE version 4.0 genitourinary toxicity occurred in 11/368 (3.0%) men, but was not severe (grade ≥ 3); total toxicity was similar between the prostate volume groups (P = 0.86). Continuous prostate volume neither correlated with (P = 0.50) nor predicted late genitourinary toxicity (univariate odds ratio 0.99, 95% confidence interval 0.96-1.02). The total IPSS cohort, group 1 (<30 g) and 2 (30-60 g), showed a similar IPSS trend of elevation from pretreatment baseline to one month post-IMRT (each P < 0.01), then a reduction to baseline at one year (each P < 0.01). Group 3 (>60 g) had the highest pretreatment IPSS, but uniquely showed a better urinary symptom trend than the smaller volume groups, with similar IPSS from baseline to one month post-IMRT (P = 0.88) and improved post-treatment IPSS from baseline at one year (P = 0.003). CONCLUSION Pretreatment prostate volume and initial IPSS scores were not associated with increased late genitourinary toxicity after IMRT in our series. Patients with smaller prostates had an initial increase in urinary symptoms, but returned to baseline at one year. Larger prostate glands (>60 g) had comparatively worse pretreatment symptoms, but at one year showed an overall improvement in IPSS versus baseline.
منابع مشابه
Early toxicity of moderate hypofractionated volumetric modulated Arc radiotherapy for localized prostate cancer
Background: Based on the radiation biology model of prostate cancer, hypofractionated radiotherapy can improve the treatment outcomes without increasing toxicity. Although hypofractionated radiotherapy is implemented over a short period of time, it is more convenient and cheaper compared with conventional fractionated treatment. The aim of this study was to investigate the early toxicity of mod...
متن کاملComparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy
Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...
متن کامل3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis
Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...
متن کاملThe Relationship between the Different Prostate Intensity Modulated Radiation Therapy Techniques and Patient’s Anatomical Parameters
Introduction: Intensity Modulated Radiotherapy (IMRT) is a common method for treating prostate cancers. Different IMRT methods can apply for irradiating the prostate, but there is not clear that which of these methods can provide better dose distribution for each patient individually. Therefore, the aim of this study was to evaluate the relationship between the different prosta...
متن کاملAssessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot, Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer
Introduction: Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf c...
متن کامل