Persistent Corneal Decompensation due to Anterior Dislocation of Soemmering Ring Cataract

نویسندگان

  • Travis Peck
  • Shruti Aggarwal
  • Sandra Johnson
چکیده

Purpose We present a case of a patient with Soemmering ring after cataract surgery and a potential complication that can arise as a result of its presence. Observations A patient with history of ruptured globe status after repair and lensectomy, complicated by aphakic secondary open angle glaucoma, was referred for management of second injury to the same eye. This injury resulted in Soemmering ring dislocation into the anterior chamber. The cortical material caused a significant increase in intraocular pressure and corneal decompensation. Surgical removal of the Soemmering ring and Ahmed glaucoma tube implant was performed with control of intraocular pressures; however corneal edema could not be reversed. Conclusions and Importance This case report illustrates the serious consequences that can be caused by Soemmering rings without early surgical intervention. Care must be taken to completely remove cortical material during cataract surgery to prevent their formation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Congenital aniridia with cataract: case series

BACKGROUND This study evaluates patients with congenital aniridia and cataract who underwent phacoemulsification, capsular tension ring placement, and foldable intraocular lens implantation. METHODS In this prospective case series, 10 patients (17 eyes) underwent cataract surgery via a 3.2 mm clear corneal incision. A continuous circular capsulorhexis with <6 mm diameter was employed. A capsu...

متن کامل

Corneal edema and penetrating keratoplasty after anterior chamber phakic intraocular lens implantation.

Phakic intraocular lens (IOL) implantation is an increasingly popular option in surgical correction of refractive error. To date, reports of long-term morbidity are infrequent in the literature. We encountered 3 patients who experienced corneal decompensation and cataract progression following angle-fixated anterior chamber phakic IOL placement.

متن کامل

Retained IOL fragment and corneal decompensation after pseudophakic IOL exchange.

A 72-year-old man had exchange of a foldable silicone multifocal intraocular lens (IOL) by transection, removal, and monofocal IOL replacement. One month after the exchange, irreversible corneal edema developed and penetrating keratoplasty was performed. At the time of the corneal transplant, a small silicone fragment was discovered in and removed from the anterior chamber. Histologic evaluatio...

متن کامل

Pseudophakic angle-closure from a Soemmering ring

BACKGROUND Report of three patients with pseudophakic angle-closure from a Soemmering ring. Three mechanisms of the Soemmering ring induced pseudophakic angle-closure in three patients were demonstrated by meticulous anterior segment examination and ultrasound biomicroscopic (UBM) analysis. CASE PRESENTATION In the first case, the Soemmering-capsule-IOL complex caused relative pupillary block...

متن کامل

Management of anterior chamber dislocation of a dexamethasone intravitreal implant: a case report

BACKGROUND Ozurdex is a 700 mcg dexamethasone intravitreal implant, approved for the management of macular edema secondary to retinal vein occlusion, and other related pathoglogiesAnterior chamber dislocation of Ozurdex represents an uncommon complication of the intravitreal injection, which can be managed by repositioning the implant into the vitreous cavity. We describe the case of a successf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2017  شماره 

صفحات  -

تاریخ انتشار 2017