Biomechanical characterization of keratoconus corneas ex vivo with Brillouin microscopy.

نویسندگان

  • Giuliano Scarcelli
  • Sebastien Besner
  • Roberto Pineda
  • Seok Hyun Yun
چکیده

PURPOSE Loss of corneal strength is a central feature of keratoconus progression. However, it is currently difficult to measure corneal mechanical changes noninvasively. The objective of this study is to evaluate if Brillouin optical microscopy can differentiate the mechanical properties of keratoconic corneas versus healthy corneas ex vivo. METHODS We obtained eight tissue samples from healthy donor corneas used in Descemet's stripping endothelial keratoplasty (DSEK) and 10 advanced keratoconic corneas from patients undergoing deep anterior lamellar keratoplasty (DALK). Within 2 hours after surgery, a confocal Brillouin microscope using a monochromatic laser at 532 nm was used to map the Brillouin frequency shifts of the corneas. RESULTS The mean Brillouin shift in the anterior 200 μm of the keratoconic corneas at the cone was measured to be 7.99 ± 0.10 GHz, significantly lower than 8.17 ± 0.06 GHz of the healthy corneas (P < 0.001). The Brillouin shift in the keratoconic corneas decreased with depth from the anterior toward posterior regions with a steeper slope than in the healthy corneas (P < 0.001). Within keratoconic corneas, the Brillouin shift in regions away from the apex of the cone was significantly higher than within the cone region (P < 0.001). CONCLUSIONS Brillouin measurements revealed notable differences between healthy and keratoconic corneas. Importantly, Brillouin imaging showed that the mechanical loss is primarily concentrated within the area of the keratoconic cone. Outside the cone, the Brillouin shift was comparable with that of healthy corneas. The results demonstrate the potential of Brillouin microscopy for diagnosis and treatment monitoring of keratoconus.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spatially-resolved Brillouin spectroscopy reveals biomechanical changes in early ectatic corneal disease and post-crosslinking in vivo

Mounting evidence connects the biomechanical properties of tissues to the development of eye diseases such as keratoconus, a common disease in which the cornea thins and bulges into a conical shape. However, measuring biomechanical changes in vivo with sufficient sensitivity for disease detection has proved challenging. Here, we present a first largescale study (~200 subjects, including normal ...

متن کامل

Multiphoton fluorescence and second harmonic generation imaging of the structural alterations in keratoconus ex vivo.

PURPOSE To demonstrate the application of multiphoton fluorescence (MF) and second harmonic generation (SHG) microscopy for ex vivo characterization of the structural alterations of human corneas due to keratoconus. METHODS Buttons of keratoconic corneas derived from penetrating keratoplasty were sent for structural analysis with a custom-built multiphoton microscope. Fluorescence detected wi...

متن کامل

Imaging Microscopic Features of Keratoconic Corneal Morphology

PURPOSE To search for gold-standard histology indicators using alternative imaging modalities in keratoconic corneas. METHODS Prospective observational case-control study. Fourteen keratoconic corneas and 20 normal corneas (10 in vivo healthy subjects and 10 ex vivo donor corneas) were examined. Images of corneas were taken by spectral domain optical coherence tomography (SD-OCT) and in vivo ...

متن کامل

The mystery of collagen cross-linking when it comes to in vivo biomechanical measurements.

To the Editor: Bak-Nielsen et al. recently reported on the dynamic assessment of keratoconus and the effects of corneal cross-linking (CXL).1 The authors described the corneal deformation during rapidly applied force via an air jet using ultra high-speed Scheimpflug technology (Corvis ST; Oculus Optikgeräte GmbH, Wetzlar, Germany).1 Patients with both untreated and CXL-treated keratoconus were ...

متن کامل

Mapping the corneal sub-basal nerve plexus in keratoconus by in vivo laser scanning confocal microscopy.

PURPOSE To produce a two-dimensional reconstruction map of the living corneal sub-basal nerve plexus in keratoconus with in vivo confocal microscopy. METHODS Four eyes of four subjects with keratoconus were examined by slit lamp biomicroscopy, Orbscan II slit-scanning elevation topography (Bausch & Lomb Surgical, Rochester, NY), and laser scanning in vivo confocal microscopy with the Heidelbe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 55 7  شماره 

صفحات  -

تاریخ انتشار 2014