Diagnostic Accuracy of 18F-FDG PET/CT in Infective Endocarditis and Implantable Cardiac Electronic Device Infection: A Cross-Sectional Study.

نویسندگان

  • Ulises Granados
  • David Fuster
  • Juan M Pericas
  • Jaime L Llopis
  • Salvador Ninot
  • Eduard Quintana
  • Manel Almela
  • Carlos Paré
  • José M Tolosana
  • Carlos Falces
  • Asuncion Moreno
  • Francesca Pons
  • Francisco Lomeña
  • Jose M Miro
چکیده

Early diagnosis of infective endocarditis (IE) is based on the yielding of blood cultures and echocardiographic findings. However, they have limitations and sometimes the diagnosis is inconclusive, particularly in patients with prosthetic valves (PVs) and implantable cardiac electronic devices (ICEDs). The primary aim of this study was to evaluate the diagnostic accuracy of 18F-FDG PET/CT in patients with suspected IE and ICED infection. METHODS A prospective study with 80 consecutive patients with suspected IE and ICED infection (65 men and 15 women with a mean age of 68 ± 13 y) between June 2013 and May 2015 was performed in our hospital. The inclusion criteria were clinically suspected IE and ICED infection at the following locations: native valve (NV) (n = 21), PV (n = 29), or ICED (n = 30) (automatic implantable defibrillator [n = 11] or pacemaker [n = 19]). Whole-body 18F-FDG PET/CT with a myocardial uptake suppression protocol with unfractionated heparin was performed in all patients. The final diagnosis of infection was established by the IE Study Group according to the clinical, echocardiographic, and microbiologic findings. RESULTS A final diagnosis of infection was confirmed in 31 patients: NV (n = 6), PV (n = 12), and ICED (n = 13). Sensitivity, specificity, positive predictive value, and negative predictive value for 18F-FDG PET/CT were 82%, 96%, 94%, and 87%, respectively. 18F-FDG PET/CT was false-negative in all cases with infected NV. 18F-FDG PET/CT was able to reclassify 63 of 70 (90%) patients initially classified as possible IE by modified Duke criteria. In 18 of 70 cases, 18F-FDG PET/CT changed possible to definite IE (26%) and in 45 of 70 cases changed possible to rejected IE (64%). Additionally, 18F-FDG PET/CT identified 8 cases of septic embolism and 3 of colorectal cancer in patients with a final diagnosis of IE. CONCLUSION 18F-FDG PET/CT proved to be a useful diagnostic tool in suspected IE and ICED infection and should be included in the diagnostic algorithm for early diagnosis. 18F-FDG PET/CT is not useful in the diagnosis of IE in NV but should be also considered in the initial assessment of this complex scenario to rule out extracardiac complications and possible neoplasms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of extra-cardiac hypermetabolic foci by [18F]FDG PET/CT in case of infective endocarditis and post antibiotic therapy response assessment

The diagnosis of prosthetic valve endocarditis continues to present a diagnostic challenge, due to the lower sensitivity of the modified Duke criteria and a higher percentage of negative or inconclusive echocardiography results. Diagnostic delay might result in significant morbidity/mortality. Imaging modalities like 2-[18F]fluoro-2-deoxy-D-glucose positron emission tomography/comput...

متن کامل

Diagnostic yield of FDG positron-emission tomography/computed tomography in patients with CEID infection: a pilot study.

AIMS Whole body imaging with (18)F-fluorodeoxyglucose positron-emission tomography/computed tomography (FDG PET/CT) has proven useful in various infectious diseases. The purpose of this pilot study was to assess the diagnostic yield of FDG PET/CT in patients with cardiac implantable electronic device (CIED) infection. METHODS AND RESULTS A total of 21 patients with CIED infection were prospec...

متن کامل

Role of radionuclide imaging for diagnosis of device and prosthetic valve infections

Cardiovascular implantable electronic device (CIED) infection and prosthetic valve endocarditis (PVE) remain a diagnostic challenge. Cardiac imaging plays an important role in the diagnosis and management of patients with CIED infection or PVE. Over the past few years, cardiac radionuclide imaging has gained a key role in the diagnosis of these patients, and in assessing the need for surgery, m...

متن کامل

Positron Emission Tomography and Single-Photon Emission Computed Tomography Imaging in the Diagnosis of Cardiac Implantable Electronic Device Infection: A Systematic Review and Meta-Analysis.

BACKGROUND The use of cardiac implantable electronic devices (CIED) is increasing, and their associated infections result in significant morbidity and mortality. The introduction of better cardiac imaging techniques could be useful for diagnosing this condition and guiding therapy. Our objective was to systematically assess the diagnostic accuracy of Fluor-18-fluorodeoxyglucose positron emissio...

متن کامل

Diagnostic value of imaging in infective endocarditis: a systematic review.

Sensitivity and specificity of the modified Duke criteria for native valve endocarditis are both suboptimal, at approximately 80%. Diagnostic accuracy for intracardiac prosthetic material-related infection is even lower. Non-invasive imaging modalities could potentially improve diagnosis of infective endocarditis; however, their diagnostic value is unclear. We did a systematic literature review...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 57 11  شماره 

صفحات  -

تاریخ انتشار 2016