Surgical Treatment for Unstable Distal Clavicle Fracture with Micromovable and Anatomical Acromioclavicular Plate
نویسندگان
چکیده
Between 2006 and 2009, 18 patients of distal clavicle fracture were treated with micro-movable and anatomical acromioclavicular plate (MAAP) in our department. According to the Neer's classification, all cases were unstable with type IIA (12 cases) and type IIB (6 cases). Functional outcome was evaluated using the Karlsson's criteria. The mean follow-up was 18 months (range, 12-36months). No postoperative plate screws complication was observed. Osseous union could be achieved at a mean time of 12 weeks after operation in 18 patients (range, 8 -16 weeks). According to Karlsson's criteria, radiographic appearances and postoperative shoulder functional recovery revealed a good and excellent rate in these cases. We conclude that surgical treatment using MAAP seems to be a good option for unstable type II fractures of the distal clavicle. This technique allows for reliable fixation with early functional exercises and functional recovery.
منابع مشابه
Functional Results of Unstable (Type 2) Distal Clavicle Fractures Treated with Superior Anterior Locking Plate
Background: The treatment of distal clavicle fracture is always a challenge, as it is mostly unstable and has higherrate of delayed union, malunion, non-union and associated acromioclavicular arthritis. So the management of thesefractures remains controversial. The purpose of this study is to evaluate the functional results of Type 2 distal endclavicle fractures treated with superior anterior l...
متن کاملSimultaneous of Mid Third Clavicle Fracture and Type 3 Acromioclavicular Joint Dislocation; A Case Report
Simultaneous mid third clavicle fracture and acromioclavicular joint dislocation is a rare combination injury, as a result of high-energy trauma. We report a patient with a middle third clavicle fracture and ipsilateral grade three-acromioclavicular joint dislocation, which is a rare combination. The patient wanted to get back to work as soon as possible, so the fracture was fixed with recons...
متن کاملComparison of Internal Fixations for Distal Clavicular Fractures Based on Loading Tests and Finite Element Analyses
It is difficult to apply strong and stable internal fixation to a fracture of the distal end of the clavicle because it is unstable, the distal clavicle fragment is small, and the fractured region is near the acromioclavicular joint. In this study, to identify a superior internal fixation method for unstable distal clavicular fracture, we compared three types of internal fixation (tension band ...
متن کاملAcromioclavicular Joint Dislocation with Ipsilateral Mid Third Clavicle, Mid Shaft Humerus and Coracoid Process Fracture – A Case Report
INTRODUCTION The clavicle, humerus and acromioclavicular (AC) joint separately are very commonly involved in traumatic injuries around the shoulder. Acromioclavicular joint dislocation with distal clavicle fracture is a well recognized entity in clinical practice. AC joint dislocation with mid shaft clavicle fracture is uncommon and only few cases have been reported in literature. However, to t...
متن کاملClinical therapeutic effects of AO/ASIF clavicle hook plate on distal clavicle fractures and acromioclavicular joint dislocations
OBJECTIVE The aim of this study was to evaluate the security and effectiveness of AO/ASIF clavicle hook plate in the treatment of distal clavicle fractures and acromioclavicular joint dislocations. METHODS One hundred patients with distal clavicle fractures and acromioclavicular joint dislocations who were admitted in our hospital from January 2012 to January 2013 were selected as the study s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -