Influence of longitudinal position on the evolution of steady-state signal in cardiac cine balanced steady-state free precession imaging
نویسندگان
چکیده
Background Emerging quantitative cardiac magnetic resonance imaging (CMRI) techniques use cine balanced steady-state free precession (bSSFP) to measure myocardial signal intensity and probe underlying physiological parameters. This correlation assumes that steady-state is maintained uniformly throughout the heart in space and time. Purpose To determine the effects of longitudinal cardiac motion and initial slice position on signal deviation in cine bSSFP imaging by comparing two-dimensional (2D) and three-dimensional (3D) acquisitions. Material and Methods Nine healthy volunteers completed cardiac MRI on a 1.5-T scanner. Short axis images were taken at six slice locations using both 2D and 3D cine bSSFP. 3D acquisitions spanned two slices above and below selected slice locations. Changes in myocardial signal intensity were measured across the cardiac cycle and compared to longitudinal shortening. Results For 2D cine bSSFP, 46% ± 9% of all frames and 84% ± 13% of end-diastolic frames remained within 10% of initial signal intensity. For 3D cine bSSFP the proportions increased to 87% ± 8% and 97% ± 5%. There was no correlation between longitudinal shortening and peak changes in myocardial signal. The initial slice position significantly impacted peak changes in signal intensity for 2D sequences (P < 0.001). Conclusion The initial longitudinal slice location significantly impacts the magnitude of deviation from steady-state in 2D cine bSSFP that is only restored at the center of a 3D excitation volume. During diastole, a transient steady-state is established similar to that achieved with 3D cine bSSFP regardless of slice location.
منابع مشابه
Balanced Phase Contrast Steady State Free Precession (PC-SSFP): Velocity Encoding by Gradient Inversion
chnique for velocity measurements (PC-SSFP) is presented that combines CINE Phase Contrast (PC) MRI and balanced Steady State Free Precession. Sensitivity to through plane velocities was established by inverting (i.e. negating) the slice select gradient for consecutively executed balanced SSFP pulse sequences. Velocity sensitivity (venc) could be adjusted by increasing the first moments of the ...
متن کاملRespiratory and cardiac self-gated free-breathing cardiac CINE imaging with multiecho 3D hybrid radial SSFP acquisition.
A respiratory and cardiac self-gated free-breathing three-dimensional cine steady-state free precession imaging method using multiecho hybrid radial sampling is presented. Cartesian mapping of the k-space center along the slice encoding direction provides intensity-weighted position information, from which both respiratory and cardiac motions are derived. With in plan radial sampling acquired a...
متن کاملCardiac BOLD Imaging with Cine 2D-Balanced SSFP
Introduction Detecting changes in oxygen content in tissues can aid in understanding pathological processes. In the MR environment, changes in blood oxygen saturation are accompanied by local magnetic field variations sampled by the spins, allowing for acquisition of oxygen-weighted images [1-2]. This observation has been exploited in identifying myocardial oxygen deficits that originate from c...
متن کاملClinical validation of free breathing Respiratory Triggered Retrospectively Cardiac Gated Cine Steady-State Free Precession (RT-SSFP) imaging in sedated children
Background Cine steady-state free precession (SSFP) is the preferred sequence for ventricular function evaluation. However, SSFP demands uninterrupted RF excitation to maintain steady-state (SS) during suspended respiration. This is feasible in adults who can perform breath-holding (BH), but is difficult to accomplish in sedated or uncooperative children. To overcome this, many pediatric groups...
متن کاملQuantitative assessment of temporal stability of the myocardial signal and relative blood to myocardial contrast in free breathing respiratory triggered retrospectively cardiac gated cine steady-state free precession (RT-SSFP) imaging
Background The SSFP sequence must attain and maintain the magnetization steady state (SS) as any interruption will entail severe imaging artifacts. In this work: (a) we propose quantitative metrics to assess the temporal stability of the myocardial signal and the blood to myocardial contrast during a cine SSFP sequence; and (b) evaluate the performance of three cine bSSFP acquisitions using the...