Doppler assessment of prosthetic valve orifice area. An in vitro study.

نویسندگان

  • H Baumgartner
  • S S Khan
  • M DeRobertis
  • L S Czer
  • G Maurer
چکیده

BACKGROUND Although Doppler echocardiography has been shown to be accurate in assessing stenotic orifice areas in native valves, its accuracy in evaluating the prosthetic valve orifice area remains undetermined. METHODS AND RESULTS Doppler-estimated valve areas were studied for their agreement with catheter-derived Gorlin effective orifice areas and their flow dependence in five sizes (19/20-27 mm) of St. Jude, Medtronic-Hall, and Hancock aortic valves using a pulsatile flow model. Doppler areas were calculated three ways: using the standard continuity equation; using its simplified modification (peak flow/peak velocity); and using the Gorlin equation with Doppler pressure gradients. The results were compared with Gorlin effective orifice areas derived from direct flow and catheter pressure measurements. Excellent correlation between Gorlin effective orifice areas and the three Doppler approaches was found in all three valve types (r = 0.93-0.99, SEE = 0.07-0.11 cm2). In Medtronic-Hall and Hancock valves, there was only slight underestimation by Doppler (mean difference, 0.003-0.25 cm2). In St. Jude valves, however, all three Doppler methods significantly underestimated effective orifice areas derived from direct flow and pressure measurements (mean difference, 0.40-0.57 cm2) with differences as great as 1.6 cm2. In general, the modified continuity equation calculated the largest Doppler areas. When orifice areas were calculated from the valve geometry using the area determined from the inner valve diameter reduced by the projected area of the opened leaflets, Gorlin effective orifice areas were much closer to the geometric orifice areas than Doppler areas (mean difference, 0.40 +/- 0.31 versus 1.04 +/- 0.20 cm2). In St. Jude and Medtronic-Hall valves, areas calculated by either technique did not show a consistent or clinically significant flow dependence. In Hancock valves, however, areas calculated by both the continuity equation and the Gorlin equation decreased significantly (p less than 0.001) with low flow rates. CONCLUSIONS Doppler echocardiography using either the continuity equation or Gorlin formula allows in vitro calculation of Medtronic-Hall and Hancock effective valve orifice areas but underestimates valve areas in St. Jude valves. This phenomenon is due to localized high velocities in St. Jude valves, which do not reflect the mean velocity distribution across the orifice. Valve areas are flow independent in St. Jude and Medtronic-Hall prostheses but decrease significantly with low flow in Hancock valves, suggesting that bioprosthetic leaflets may not open fully at low flow rates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Doppler Assessment of Prosthetic Valve Orifice Area

Background. Although Doppler echocardiography has been shown to be accurate in assessing stenotic orifice areas in native valves, its accuracy in evaluating the prosthetic valve orifice area remains undetermined. Methods and Results. Doppler-estimated valve areas were studied for their agreement with catheterderived Gorlin effective orifice areas and their flow dependence in five sizes (19/20-2...

متن کامل

Application of color Doppler flow mapping to calculate orifice area of St Jude mitral valve.

BACKGROUND The effective orifice area (EOA) of a prosthetic valve is superior to transvalvular gradients as a measure of valve function, but measurement of mitral prosthesis EOA has not been reliable. METHODS AND RESULTS In vitro flow across St Jude valves was calculated by hemispheric proximal isovelocity surface area (PISA) and segment-of-spheroid (SOS) methods. For steady and pulsatile con...

متن کامل

Evaluation of Björk-Shiley prosthetic valves by real-time two-dimensional Doppler echocardiographic flow mapping.

We studied the value of two-dimensional Doppler echocardiographic color flow mapping for identifying normal transvalve flow profiles and valve malfunction in 20 patients with Björk-Shiley prosthetic valves. Seven patients had Björk-Shiley prosthetic valves in the aortic position alone, seven in the mitral position, and six had prosthetic valves in both the aortic and mitral positions. In 10 pat...

متن کامل

Transcranial Doppler application for risk assessment of stroke in patients with mechanical mitral valve

Introduction: Observing microembolic signals in brain vessels by transcranial Doppler technology is a very common finding in patients with mechanical heart valve. These signals are almost always clinically asymptomatic. The aim of this study was assessment of transcranial Doppler in detecting probability of stroke in patients with mechanical heart valve. Methods: This descriptive study was ca...

متن کامل

Application of color Doppler flow mapping to calculate effective regurgitant orifice area. An in vitro study and initial clinical observations.

BACKGROUND Analogous to stenotic valve area in the assessment of valvular stenosis, regurgitant orifice area (ROA) represents a fundamental parameter to assess valvular insufficiency. However, this parameter has not been routinely available up to now. In this study, we introduce the concept and provide the methodology to calculate regurgitant orifice area noninvasively, based on the analysis of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 85 6  شماره 

صفحات  -

تاریخ انتشار 1992