Right heart dysfunction after left ventricular assist device implantation: a comparison of the pulsatile HeartMate I and axial-flow HeartMate II devices.
نویسندگان
چکیده
BACKGROUND Right heart dysfunction confers significant morbidity and mortality after left ventricular assist device implantation and historically occurs in as many as a third of patients. It is unknown whether newer axial flow pumps have a different impact on postimplant right heart dysfunction. We compared the incidence of right heart dysfunction after implantation of the pulsatile HeartMate I (XVE) and the continuous flow HeartMate II left ventricular assist device. METHODS We retrospectively reviewed patients who underwent HeartMate I or HeartMate II implantation between June 2000 and March 2007. Right heart dysfunction was defined as inotropic/vasodilator support for 14 or more consecutive days or the need for a right ventricular assist device, or both. RESULTS Seventy-seven patients underwent HeartMate implantation; 43 received a HeartMate I and 34 received a HeartMate II, for a mean left ventricular assist device support time of 202 and 160 days, respectively. Operative mortality was lower for HeartMate II patients (28% versus 15%; p = 0.26). The HeartMate II patients had lower preoperative right ventricular stroke work index. Pulmonary vascular resistance index, right ventricular stroke work index, and pulmonary and right atrial pressures improved and were similar between groups postoperatively. Overall, right heart dysfunction developed in 35% of HeartMate I patients (15 of 43) and 41% of HeartMate II patients (14 of 34; p = 0.63). Fewer HeartMate II patients (2) than HeartMate I patients (5) required 7 or more days of epinephrine, whereas more HeartMate II patients (7) than HeartMate I patients (5) required 7 or more days of milrinone. Six HeartMate I and 3 HeartMate II patients required right ventricular assist device implantation for right heart failure. Survival was similar (p = 0.7) between groups at, respectively, 3 (63% versus 62%), 6 (58% versus 58%), and 12 months (49% versus 48%). CONCLUSIONS Right heart dysfunction is a persistent clinical problem after left ventricular assist device placement. We report the first study comparing the incidence of right heart dysfunction after HeartMate I versus HeartMate II implantation. Although the incidence of right heart dysfunction was similar, fewer HeartMate II patients required right ventricular assist device placement and fewer required pure inotropic support for right heart failure.
منابع مشابه
Hemodynamic and exercise performance with pulsatile and continuous-flow left ventricular assist devices.
BACKGROUND Continuous-flow rotary pumps with axial design are increasingly used for left ventricular assist support. The efficacy of this design compared with pulsatile, volume displacement pumps, with respect to characteristics of left ventricular unloading, and exercise performance remains largely unstudied. METHODS AND RESULTS Thirty-four patients undergoing implantation with a pulsatile, ...
متن کاملAcquired von Willebrand syndrome after exchange of the HeartMate XVE to the HeartMate II ventricular assist device.
Instead of pulsatile ventricular assist devices an increasing number of nonpulsatile ventricular assist devices are introduced to clinical practice. The different flow characteristics of this new technique lead to alteration in shear stress on blood components, which may affect the coagulation system. Repeated von Willebrand factor analyses were performed in a patient who first was implanted wi...
متن کاملInitial clinical experience with the HeartMate II axial-flow left ventricular assist device.
The redesigned HeartMate II, an axial-flow left ventricular assist device, is simpler, smaller, and easier to operate than are pulsatile pumps. These design characteristics should make the HeartMate II more reliable and durable and broaden the eligible population base. We implanted the HeartMate II in 43 patients (average age, 42 yr). The indication for use was bridge-to-heart transplantation i...
متن کاملRight ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: incidence, risk factors, and effect on outcomes.
OBJECTIVE The aim of this study was to evaluate the incidence, risk factors, and effect on outcomes of right ventricular failure in a large population of patients implanted with continuous-flow left ventricular assist devices. METHODS Patients (n = 484) enrolled in the HeartMate II left ventricular assist device (Thoratec, Pleasanton, Calif) bridge-to-transplantation clinical trial were exami...
متن کاملFactors influencing the rate of flow through continuous-flow left ventricular assist devices at rest and with exercise.
T he heart failure (HF) community has witnessed a rapid evolution in mechanical circulatory support over the past decade. Following publication of the pivotal HeartMate II trials, continuous-flow left ventricular assist devices (cfLVADs) with an axial rotor (e.g., HeartMate II) quickly replaced the first-generation, pulsatile devices as both a bridge to transplant and as destination therapy for...