Experimental Study on the Fire Resistance Performance of Prestressed Composite Beam with Corrugated Web under Standard Fire with Loading Condition

نویسندگان

  • Heung-Youl Kim
  • Hyung-Jun Kim
  • Kyung-Hoon Park
چکیده

In this study, fire resistance tests were performed on a conventional slim floor beam and a prestressed composite beam with corrugated webs, which is suitable for a long-span structure with a reduction in story height by utilizing the prestress and accordion effect. In the fire test program, the ISO 834 standard fire curve was adopted. Key test variables were the effect of prestress, shape of corrugated webs, and thickness of sprayed fireproofing material. All of the test specimens demonstrated enhanced fire resistance performance exceeding the expected performance level. The prestressed composite beams with corrugated webs especially showed excellent fire performance, considering these specimens had thin fireproofing thickness compared to the conventional slim floor specimen.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transient High-temperature Stress Relaxation of Prestressing Tendons in Unbonded Construction

Unbonded post-tensioned (UPT) flat plate concrete slabs are popular for modern continuous multiple bay floor assemblies due to economic and sustainability benefits (reductions in slab thickness and building selfweight) and structural advantages (decreased deflections over larger spans). Only limited research has been conducted on the performance of UPT flat plate slabs under fire conditions, ye...

متن کامل

مطالعه آزمایشگاهی رفتار اتصالات عرشه سکوهای نفتی در آتش‌سوزی

Beam-to-column connections have been found to be of great significance in influencing structural behavior at ambient and elevated temperatures. Observations from full-scale fire tests and damaged structures confirm that connections have a considerable effect on the stability time of structural components in fire. Due to the high cost of elevated temperature tests, adequate experimental data abo...

متن کامل

Experimental Study on Fire Resistance Performance of a Hollow Slab Using a Lightweight Hollow Sphere

This study evaluates the fire resistance performance (1–2h) of a reinforced concrete (RC) structure-void slab using a lightweight hollow sphere, which can reduce the unnecessary dynamic of removing the central concrete. For this experiment, we set up the depth of the concrete cover, live load, and span length as the factors. The result comes out with 50 mm cover depth of the RC structure hollow...

متن کامل

Experimental Study on Double-Walled Copper and Carbon/Epoxy Composite Tubes under the Axial Loading

This paper investigates axial compression process of multi-layered tubes with circular cross-section under the axial loading in the quasi-static condition using experimental method. Some specimens are prepared in seven different groups, namely; empty carbon/epoxy composite tubes, solid carbon/epoxy composite rods, empty copper tubes, composite tubes with silicon sealant filler, concentrically s...

متن کامل

کرنش نهایی و درجه ناهمسان گردی در ورق های کامپوزیتی موج دار

In some applications such as morphing technology, high strain and anisotropic behavior are considered a good advantage. The corrugated composite sheets due to their special geometries have a potential of high deflection under axial loading. In this research, to investigate the strain and anisotropic behavior of corrugated composite sheets some glass/epoxy samples with Quasi-sinusoidal, trapezoi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014