Optimized murine lung preparation for detailed structural evaluation via micro-computed tomography.

نویسندگان

  • Dragos M Vasilescu
  • Lars Knudsen
  • Matthias Ochs
  • Ewald R Weibel
  • Eric A Hoffman
چکیده

Utilizing micro-X-ray CT (μCT) imaging, we sought to generate an atlas of in vivo and intact/ex vivo lungs from normal murine strains. In vivo imaging allows visualization of parenchymal density and small airways (15-28 μm/voxel). Ex vivo imaging of the intact lung via μCT allows for improved understanding of the three-dimensional lung architecture at the alveolar level with voxel dimensions of 1-2 μm. μCT requires that air spaces remain air-filled to detect alveolar architecture while in vivo structural geometry of the lungs is maintained. To achieve these requirements, a fixation and imaging methodology that permits nondestructive whole lung ex vivo μCT imaging has been implemented and tested. After in vivo imaging, lungs from supine anesthetized C57Bl/6 mice, at 15, 20, and 25 cmH(2)O airway pressure, were fixed in situ via vascular perfusion using a two-stage flushing system while held at 20 cmH(2)O airway pressure. Extracted fixed lungs were air-dried. Whole lung volume was acquired at 1, 7, 21, and >70 days after the lungs were dried and served as validation for fixation stability. No significant shrinkage was observed: +8.95% change from in vivo to fixed lung (P = 0.12), -1.47% change from day 1 to day 7 (P = 0.07), -2.51% change from day 1 to day 21 (P = 0.05), and -4.90% change from day 1 to day 70 and thereafter (P = 0.04). μCT evaluation showed well-fixed alveoli and capillary beds correlating with histological analysis. A fixation and imaging method has been established for μCT imaging of the murine lung that allows for ex vivo morphometric analysis, representative of the in vivo lung.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ex vivo micro-computed tomography analysis of bleomycin-induced lung fibrosis for preclinical drug evaluation.

Research into the pathogenesis underlying the development of idiopathic pulmonary fibrosis is hampered by a repertoire of animal models that fail to recapitulate all the features of the human disease. Better use and understanding of what the animal models represent may improve clinical predictability. We interrogated ex vivo micro-computed tomography (CT) as a novel end-point measure in the mou...

متن کامل

Nano-Computed Tomography: Technique and Applications.

UNLABELLED Nano-computed tomography (nano-CT) is an emerging, high-resolution cross-sectional imaging technique and represents a technical advancement of the established micro-CT technology. Based on the application of a transmission target X-ray tube, the focal spot size can be decreased down to diameters less than 400 nanometers (nm). Together with specific detectors and examination protocols...

متن کامل

CALL FOR PAPERS Real-time Visualization of Lung Function: from Micro to Macro Evaluation of cigarette smoke-induced emphysema in mice using quantitative micro-computed tomography

Sasaki M, Chubachi S, Kameyama N, Sato M, Haraguchi M, Miyazaki M, Takahashi S, Betsuyaku T. Evaluation of cigarette smokeinduced emphysema in mice using quantitative micro-computed tomography. Am J Physiol Lung Cell Mol Physiol 308: L1039–L1045, 2015. First published March 27, 2015; doi:10.1152/ajplung.00366.2014.—Chronic cigarette smoke (CS) exposure provokes variable changes in the lungs, an...

متن کامل

Evaluation of Root Canal Preparation Using Rotary System and Hand Instruments Assessed by Micro-Computed Tomography

BACKGROUND Complete mechanical preparation of the root canal system is rarely achieved. Therefore, the purpose of this study was to evaluate and compare the root canal shaping efficacy of ProTaper rotary files and standard stainless steel K-files using micro-computed tomography. MATERIAL AND METHODS Sixty extracted upper second premolars were selected and divided into 2 groups of 30 teeth eac...

متن کامل

Preparation and quality control of radiolabeled streptokinase for Thrombosis imaging

Background: In order to diagnose the site of thrombi, radiolabeled streptokinase can be prepared. The radiolabeled compound can be used in imaging of thrombi in many cardiovascular diseases. Materials and Methods: Streptokinase was successively labeled with [67Ga]-gallium chloride using cyclic DTPA-dianhydride. The conjugation with DTPA was optimized for concentration, time and temperature foll...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 112 1  شماره 

صفحات  -

تاریخ انتشار 2012