Heat bump on a monochromator crystal measured with X-ray grating interferometry.

نویسندگان

  • Simon Rutishauser
  • Alexander Rack
  • Timm Weitkamp
  • Yves Kayser
  • Christian David
  • Albert T Macrander
چکیده

Deformation of the first crystal of an X-ray monochromator under the heat load of a high-power beam, commonly referred to as `heat bump', is a challenge frequently faced at synchrotron beamlines. Here, quantitative measurements of the deformations of an externally water-cooled silicon (111) double-crystal monochromator tuned to a photon energy of 17.6 keV are reported. These measurements were made using two-dimensional hard X-ray grating interferometry, a technique that enables in situ at-wavelength wavefront investigations with high angular sensitivity. The observed crystal deformations were of the order of 100 nm in the meridional and 5 nm in the sagittal direction, which lead to wavefront slope errors of up to 4 µrad in the meridional and a few hundred nanoradians in the sagittal direction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

X-ray Tomographic Microscopy at TOMCAT

Synchrotron-based X-ray Tomographic Microscopy is a powerful technique for fast non-destructive, high resolution quantitative volumetric investigations on diverse samples. At the TOMCAT (TOmographic Microscopy and Coherent rAdiology experimenTs) beamline at the Swiss Light Source, synchrotron light is delivered by a 2.9 T superbend. The main optical component, a Double Crystal Multilayer Monoch...

متن کامل

Diamond Monochromator for High Heat Flux Synchrotron X-ray Beams

2 Single crystal silicon has been the material of choice for x-ray monochromators for the past several decades. However, the need for suitable monochromators to handle the high heat load of the next generation synchrotron x-ray beams on the one hand and the rapid and on-going advances in synthetic diamond technology on the other make a compelling case for the consideration of a diamond monochro...

متن کامل

Abstract No berm432 A Cryogenically-Cooled Channel-Cut Crystal Monochromator Using a Helium Refrigerator and Heat Exchanger

No berm432 A Cryogenically-Cooled Channel-Cut Crystal Monochromator Using a Helium Refrigerator and Heat Exchanger L.E. Berman, D.P. Siddons, P.A. Montanez, A. Lenhard, and Z. Yin (NSLS, BNL) Beamline(s) X25, X13B Introduction: Silicon crystals at room temperature employed as x-ray monochromators on synchrotron radiation beamlines, when subjected to high power density loading, suffer thermal di...

متن کامل

In situ visualization of thermal distortions of synchrotron radiation optics

We have developed a new in situ method to measure heating-induced distortions of the surface of the first monochromator crystal exposed to high-power white synchrotron radiation beam. The method is based on recording the image of a stationary grid of dots captured by a CCD camera as reflected from the surface of a crystal with and without a heat load. The three-dimensional surface profile (heat...

متن کامل

Linear parabolic single-crystal diamond refractive lenses for synchrotron X-ray sources.

Linear parabolic diamond refractive lenses are presented, designed to withstand high thermal and radiation loads coming from upgraded accelerator X-ray sources. Lenses were manufactured by picosecond laser treatment of a high-quality single-crystal synthetic diamond. Twelve lenses with radius of curvature at parabola apex R = 200 µm, geometrical aperture A = 900 µm and length L = 1.5 mm were st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of synchrotron radiation

دوره 20 Pt 2  شماره 

صفحات  -

تاریخ انتشار 2013