Multidetector row computed tomography evaluation of the micropig kidney as a potential renal donor
نویسندگان
چکیده
Multidetector row computed tomography (MDCT) provides anatomical information about the kidney and other internal organs. Presently, the suitability of 64-channel MDCT to assess the kidney of healthy micropigs was evaluated. Morphological evaluations of the kidney and the major renal vessels of six healthy micropigs were carried out using MDCT, recording kidney volume and the diameter and length of renal arteries and veins. The mean diameters and lengths of the renal artery were 0.44 +/- 0.05 and 4.51 +/- 0.55 cm on the right side and 0.46 +/- 0.06 and 3.36 +/- 0.27 cm on the left side, respectively. The mean diameters and lengths of the renal vein were 1.44 +/- 0.52 and 4.22 +/- 1.29 cm on the right side and 1.38 +/- 0.17 and 5.15 +/- 0.87 cm on the left side, respectively. The mean volume of the right kidney was 79.3 +/- 14.5 mL and of the left kidney was 78.0 +/- 13.9 mL. The data presented in this study suggest that the MDCT offers a noninvasive, rapid, and accurate method for the evaluation of the renal anatomy in living kidney donors. It also provides sufficient information about extra-renal anatomy important for donor surgery and determination of organ suitability.
منابع مشابه
Multidetector computed tomographic angiography evaluation of micropig major systemic vessels for xenotransplantation
Due primarily to the increasing shortage of allogeneic donor organs, xenotransplantation has become the focus of a growing field of research. Currently, micropigs are the most suitable donor animal for humans. However, no standard method has been developed to evaluate the systemic vascular anatomy of micropigs and standard reference values to aid in the selection of normal healthy animals as po...
متن کاملRole of Multidetector Computed Tomography for Evaluation of Living Kidney Donors
BACKGROUND Kidney transplantation from living donors has been increased recently. Preoperative evaluation of living donor is important to select the appropriate kidney for transplantation and to decrease donor surgical complications. OBJECTIVES The aim of this study was to compare the accuracy of the use of multidetector computed tomography (MDCT) to evaluate vascular anatomy in living kidney...
متن کاملMultiple renal arteries: variations demonstrated by multidetector computed tomography angiography.
OBJECTIVE To present a case of a rare variation of the renal artery and multiple (7) renal arteries by multidetector computed tomography (MDCT) angiography. CLINICAL PRESENTATION AND INTERVENTION A 36-year-old male patient was admitted to our hospital as a potential living donor for renal transplantation. An MDCT angiography was performed using a 16-detector row CT scanner to obtain a detaile...
متن کاملComparison of cardiac function and coronary angiography between conventional pigs and micropigs as measured by multidetector row computed tomography
Pigs are the most likely source animals for cardiac xenotransplantation. However, an appropriate method for estimating the cardiac function of micropigs had not been established. Computed tomography (CT) analysis aimed at estimating cardiac function and assessing the coronary arteries has not been carried out in micropigs. This study determined the feasibility of evaluating cardiac function in ...
متن کاملThe use of multi detector computed tomography in assessing the retroaortic left renal vein and accompanying vessel anomalies.
OBJECTIVE Because renal venous variations possess potential hazards during abdominal aortic surgery or laparoscopic donor nephrectomy, the detailed preoperative evaluation of the renal vessels with angiography should be performed to avoid vascular injuries. We present multidetector row computed tomography (MDCT) findings of the retroaortic left renal vein (RLRV) with other vascular variations. ...
متن کامل