Preliminary evaluation of a robotic apparatus for the analysis of passive glenohumeral joint kinematics
نویسندگان
چکیده
BACKGROUND The shoulder has the greatest range of motion of any joint in the human body. This is due, in part, to the complex interplay between the glenohumeral (GH) joint and the scapulothoracic (ST) articulation. Currently, our ability to study shoulder kinematics is limited, because existing models isolate the GH joint and rely on manual manipulation to create motion, and have low reproducibility. Similarly, most established techniques track shoulder motion discontinuously with limited accuracy. METHODS To overcome these problems, we have designed a novel system in which the shoulder girdle is studied intact, incorporating both GH and ST motions. In this system, highly reproducible trajectories are created using a robotic actuator to control the intact shoulder girdle. High-speed cameras are employed to track retroreflective bone markers continuously. RESULTS We evaluated this automated system's capacity to reproducibly capture GH translation in intact and pathologic shoulder conditions. A pair of shoulders (left and right) were tested during forward elevation at baseline, with a winged scapula, and after creation of a full thickness supraspinatus tear. DISCUSSION The system detected differences in GH translations as small as 0.5 mm between different conditions. For each, three consecutive trials were performed and demonstrated high reproducibility and high precision.
منابع مشابه
The effect of 8-week online scapular-focused training on scapular kinematics, proprioception, and selected muscles strength in female volleyball players with Glenohumeral Internal Rotation Deficit
Introduction and aim: One of the most significant risk factors for throwing athletes is an internal rotation deficit of the shoulder joint. This study investigated 8-week online scapular-focused training on the scapular kinematics, proprioception, and strength of particular shoulder muscles in female volleyball players with Glenohumeral Internal Rotation Deficit. Methodology: The present study...
متن کاملEstimation of spinal loads using a detailed finite element model of the L4-L5 lumbar segment derived by medical imaging kinematics; a feasibility study
Introduction: Low back pain is the most prevalent orthopedic disorder and the first main cause of poor working functionality in developed as wells as many developing countries. In Absence of noninvasive in vivo measurement approaches, biomechanical models are used to estimate mechanical loads on human joints during physical activities. To estimate joint loads via musculoskelet...
متن کاملA Comparison of Glenohumeral Internal and External Range of Motion and Rotation Strength in Healthy and Individuals with Recurrent Anterior Instability
Background: The glenohumeral joint becomes dislocated more than any other major joint because it maintains a wide range of motion and its stability is inherently weak. The most common complication following acute initial shoulder dislocation is recurrent dislocation or chronic instability. Imbalance of strength and range of motion in individuals with anterior dislocation can be a contributing ...
متن کاملPosterior Capsular Plication Constrains the Glenohumeral Joint by Drawing the Humeral Head Closer to the Glenoid and Resisting Abduction
BACKGROUND Shoulder pain is a common problem, with 30% to 50% of the American population affected annually. While the majority of these shoulder problems improve, there is a high rate of recurrence, as 54% of patients experience persistent symptoms 3 years after onset. PURPOSE Posterior shoulder tightness has been shown to alter glenohumeral (GH) kinematics. Clinically, posterior shoulder con...
متن کاملA Novel Shoulder Exoskeleton Robot Using Parallel Actuation and a Passive Slip Interface
This paper presents a five degrees-of-freedom (DoF) low inertia shoulder exoskeleton. This device is comprised of two novel technologies. The first is 3DoF spherical parallel manipulator (SPM), which was developed using a new method of parallel manipulator design. This method involves mechanically coupling certain DoF of each independently actuated linkage of the parallel manipulator in order t...
متن کامل