The value of radiographic film for the characterization of intensity-modulated beams.
نویسندگان
چکیده
In this paper the performance of radiographic film (KODAK X-Omat V) for analysing intensity-modulated (IM) beams in a plane at reference depth (5 cm for 6 MV, 10 cm for 18 MV) was investigated. The field size dependence of the film response was studied for small and medium field sizes. The dose rate dependence of the response and possible effects of fractionating the dose were assessed. In the end, profiles were measured for two clinically delivered IM beams, and the results were compared with diamond detector data. We found that the response of the radiographic film increases with field size, but for field sizes up to 15 x 15 cm the deviations remain within 3% for measurements with the films in a plane at reference depth. We found that the response of the films decreases with decreasing dose rate, and that the extent of this effect differs from film batch to film batch. For clinical IM beams the effect can amount to about 9% at the location of shielded organs at risk. Also, fractionating the dose reduces the net optical density, but this effect is normally small when assessing IM beams. In low-dose regions low-energy photons have an important contribution, resulting in a higher response at these positions. This may counteract the dose rate dependence of the response. In the high-dose regions of the two IM beams that were studied, the relative dose measurements with film are within 1% of those obtained with a diamond detector, when the results of three films are averaged. In shielded organs at risk the deviations can mount to about 3%, depending on the film batch. In conclusion, radiographic film is a suitable detector for characterizing IM beams in a plane at reference depth.
منابع مشابه
Dosimetry limitations and pre-treatment dose profile correction for sliding window IMRT
Background: This work investigated the dosimetry limitations of the random and systematic uncertainties of sliding window (SW) intensity modulated radiation therapy (IMRT). Materials and Methods: A Varian 21EX linear accelerator, Pinnacle3 treatment planning system and radiographic film dosimetry was used. The limitations of the SW were studied using beam modulation ranging from 2 to 10...
متن کاملThe Quality Control of Intensity Modulated Radiation Therapy (IMRT) for ONCOR Siemens Linear Accelerators Using Film Dosimetry
Introduction Intensity Modulated Radiation Therapy (IMRT) has made a significant progress in radiation therapy centers in recent years. In this method, each radiation beam is divided into many subfields that create a field with a modulated intensity. Considering the complexity of this method, the quality control for IMRT is a topic of interest for researchers. This article is about the various ...
متن کاملGrid: A location dependent intensity modulated radiotherapy for bulky tumors
Background: An effective method for management of large and bulky malignant tumors. This treatment modality is also known as Specially Fractionated Radiation Therapy (SFRT). In this treatment technique a grid block converted the open radiation field into a series of pencil beams. Dosimetric characteristics of an external beam grid radiation field have been investigated using experimental and Mo...
متن کاملSmall photon field dosimetry using EBT2 Gafchromic film and Monte Carlo simulation
Background: Small photon fields are increasingly used in modern radiotherapy especially in intensity modulated radiation therapy (IMRT) and stereotactic radiosurgery (SRS) treatments. Accurate beam profile and central axis depth doses measurements of such beams are complicated due to the electron disequilibrium. Hence the EBT2 (external beam therapy) Gafchromic film was used for dosimetry of sm...
متن کاملThe value of EDR2 film dosimetry in compensator-based intensity modulated radiation therapy.
Radiographic or silver halide film is a well-established 2D dosimeter with an unquestioned spatial resolution. But its higher sensitivity to low-energy photons has to be taken into consideration. Metal compensators or physical modulators to deliver intensity modulated radiation therapy (IMRT) are known to change the beam energy spectrum and to produce scattered photons and contaminating electro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 47 13 شماره
صفحات -
تاریخ انتشار 2002