Effects of flange size on dividing streamlines of exterior hoods in cross drafts.
نویسندگان
چکیده
Effects of flange size on the flow patterns of an exterior circular hood subject to the influence of various uniform cross drafts were studied in an apparatus consisting of hood-model/wind-tunnel assembly. The cross draft to suction velocity ratio covered the range from 0.056 to 0.792. The flange width to hood diameter ratio spanned from 1.2 to 3.0. The hood equipped without flange was also probed. A two-component laser Doppler anemometer was used to measure the velocity field on the symmetry plane. The streamline patterns were obtained from the measured velocity data. The cross draft caused a capture envelope. The boundary of the envelope was described by a dividing streamline. It was found that the flange width presented complex effects on the capture envelope and the dividing streamline. Corresponding to a cross draft to suction velocity ratio, a critical flange width existed. If the flange width was smaller than the critical value, the dividing streamline would terminate at the downstream tip of the flange. The behaviors of the capture envelope and the dividing streamline of the hood in cross draft under different flange widths are presented and discussed.
منابع مشابه
The capture envelope of a flanged circular hood in cross drafts.
The flow patterns of an exterior circular hood subject to the influence of various uniform cross drafts were experimentally studied in an apparatus consisting of hood-model/wind-tunnel assembly. A two-component laser Doppler anemometer was employed to measure the velocity field on the symmetry plane. The streamline patterns were obtained from the measured velocity data. The cross draft caused a...
متن کاملANALYTICAL STUDY OF STEEL I-BEAM WITH STEPPED FLANGES
This paper presents a parametric study of steel I- beam with stepped flanges by using finite element analysis. Stepped flange beam is used in structures to decrease the negative bending moments near interior supports that causes failure due to buckling. Steps in the cross section can be achieved by adding cover plates to the beam flanges, changing the size of the hot rolled section, or changing...
متن کاملارایه روشی کاربردی برای ارزیابی پارامترهای طراحی هودهای سیستم تهویه مکنده موضعی در یک واحد آهنسازی
Introduction: Efficiency of hoods for local exhaust ventilation system is influenced by hood geometry, its situation relative to the process and the air volume exhausted by it. The aim of this study was to present a simple and practical method based on the standards for assessment of potential problems of ventilation system in a steel making company. Material and Method: In this cross-sect...
متن کاملبررسی کارایی هودهای سیستم تهویه مکنده موضعی در کنترل گردوغبار Fe2O3 در فرایند سرند اکساید واحد آهن سازی یکی از صنایع فولاد
Background & Objectives : Local exhaust ventilation system (LEV) is one of the most common engineering controls methods for the chemical agents in workplaces. This study aimed to determine the efficiency assessment of the LEV system for control of Fe2O3 dust in the process of oxide screen unit at iron making in steel industry . Methods : The LEV system with an extensive network...
متن کاملارزیابی عملکرد هودهای آزمایشگاهی براساس استاندارد ASHRAE 110 در
Background and Aim: Laboratory fume-hoods are the first-level protection for the laboratory staff against hazardous chemical pollutants. Considering the large numbers of personnel, especially in petrochemical industry laboratories, this project was carried out in order to assess the performance of laboratory hoods based on tracer gas (SF6).Materials and Methods: In this project 22 hoods in the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of occupational and environmental hygiene
دوره 1 5 شماره
صفحات -
تاریخ انتشار 2004