Multicenter evaluation of automated immunoturbidimetric assays for measurement of apolipoproteins A-I and B in serum and plasma.

نویسندگان

  • S E Kahn
  • R F Labbé
  • E H Pfadenhauer
  • A D Kanonchoff
  • R T Joseph
چکیده

Results of a multicenter evaluation of automated assays for measurement of apolipoproteins (apo) A-I and B with the Paramax analytical system are reported. Apo A-I and apo B response surface models were used to optimize concentrations of critical assay variables. Overall imprecision for apo A-I controls at concentrations of 1.01-1.61 g/L was 3.7-6.6%; overall imprecision for apo B controls at 1.00-1.61 g/L was 2.8-6.9%. There was no interference in apo A-I measurements. Albumin concentrations > 59 g/L resulted in a negative interference, and collection in sodium heparin caused a positive interference in apo B results. Apo A-I and apo B assays demonstrated acceptable agreement with comparative methods, although the Paramax apo B assays had a negative bias with respect to comparison methods. In 116 healthy individuals, serum apo A-I ranged from 0.97 to 2.05 g/L and serum apo B ranged from 0.51 to 1.32 g/L.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immunoturbidimetric method for routine determinations of apolipoproteins A-I and B.

A simple immunoturbidimetric method for quantifying apolipoproteins (apo) A-I and B in serum or plasma is described. A special reagent formulation, including large amounts of suitable detergents, obviates the need for a sample blank even with grossly lipemic specimens. The assay is rapid, easily automated, and thus convenient for routine work. For both apo A-I and apo B, the assay range is abou...

متن کامل

Immunological assays of apolipoproteins in plasma: methods and instrumentation.

A number of immunological techniques--radioimmunoassay, enzyme-linked immunosorbent assay (ELISA), electroimmunoassay, radial immunodiffusion, and a variety of immunoprecipitin assays--have been used to quantify apolipoproteins in plasma. This paper outlines their technical details and discusses their major advantages and drawbacks. The most sensitive procedures, RIAs and ELISAS, are best suite...

متن کامل

Effect of plasma triglyceride concentrations on the accuracy of immunoturbidimetric assays of apolipoprotein B.

We have studied the influence of triglyceride-rich particles on the analytical bias of apolipoprotein B measurements by various immunoturbidimetric methods. Three commercially available methods grossly overestimate apolipoprotein B in samples with even moderately above-normal triglyceride concentrations. This effect is due to the increased relative reactivity of very-low-density lipoproteins in...

متن کامل

Immunoturbidimetric assays for serum apolipoproteins A1 and B using Cobas Bio centrifugal analyser.

Immunoturbidimetric assays for measuring the apolipoproteins A1 and B using the Cobas Bio centrifugal analyser are described. The methods were specific, offered good sensitivity (less than 0.05 g/l) and intrabatch variability, with coefficients of variation between 2.4% and 3.5%, and were cost effective. Reference ranges were calculated for a group of civil servants, aged 35 to 55 years.

متن کامل

Automated Multiplex LC-MS/MS Assay for Quantifying Serum Apolipoproteins A-I, B, C-I, C-II, C-III, and E with Qualitative Apolipoprotein E Phenotyping.

BACKGROUND Direct and calculated measures of lipoprotein fractions for cardiovascular risk assessment suffer from analytical inaccuracy in certain dyslipidemic and pathological states, most commonly hypertriglyceridemia. LC-MS/MS has proven suitable for multiplexed quantification and phenotyping of apolipoproteins. We developed and provisionally validated an automated assay for quantification o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 40 9  شماره 

صفحات  -

تاریخ انتشار 1994