The cost effectiveness of 3D conformal radiation therapy compared with conventional techniques for patients with clinically localized prostate cancer.
نویسندگان
چکیده
BACKGROUND We previously demonstrated the advantages of three-dimensional conformal radiation therapy (3DCRT) in improved rates of biochemical (bNED) control in certain subsets of patients with clinically localized prostate cancer. However, in this era of cost consciousness and limited resources, the cost effectiveness of 3DCRT compared with conventional external beam irradiation (CRT) remains unexamined. METHODS AND MATERIALS Between October 1, 1987 and November 30, 1991, 193 patients with clinically localized prostate cancer received definitive external beam irradiation at Fox Chase Cancer Center. The 1998 Medicare fee schedule was used to determine treatment charges and to provide a reference for a national comparison. Complete charges for pretreatment work-up, treatment, and follow-up were tabulated for each patient. The mean total charges (MTC) using the Lin method of estimating medical costs was used to analyze and compare costs between groups. A matched case/control analysis was performed to further evaluate the effect of cost between techniques. The median follow-up was 72 months (range 3-118). RESULTS The overall 5-year actuarial rate of bNED control was 41% and 53%, respectively, for the CRT and 3DCRT patients (p = 0.03). The MTC for the CRT patients was $10,544.53. For the 3DCRT patients, the MTC was $8,955.48. The sample mean of the total costs from the observed deaths for the two patient groups by follow-up interval ranged from $9,800.63 to $59,635.01 for the CRT patients to $17,259.00 to $24,250.38 for the 3DCRT patients. No statistically significant difference in cost was observed between groups using the matched case/control analysis. CONCLUSION Initial work-up and treatment costs were greater for patients treated with 3DCRT compared with patients treated with conventional techniques. However, with longer follow-up, the mean total cost of treatment was not statistically different between the two treatment groups. Because of improved rates of bNED control for these patients and the increased costs associated with the treatment of a greater fraction of patients with recurrent disease following CRT, 3DCRT was cost effective for patients with clinically localized prostate cancer.
منابع مشابه
3D-Conformal Radiation Therapy and Intensity-Modulated Radiation Therapy Techniques for Laryngeal Cancer Taking Parotid Glands as Organ at Risk
Background: Three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) techniques are used for the treatment of patients with laryngeal cancer. Objective: This study aimed to investigate the effects of these 2 treatment techniques on the planning target volume (PTV) (laryngeal cancer), dose homogeneity, dose of organs at...
متن کاملComparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy
Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...
متن کامل3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis
Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...
متن کاملComparison of conventional and 3D conformal treatments using linac energies for prostate cancer
Background: To evaluate the dosimetric difference between conventional and three-dimensional conformal Radiotherapy (3D-CRT) using 6 and 18 MV X-ray photons. Materials and Methods: Computed tomography scans of 26 pelvic patients were acquired and transferred to the 3D treatment planning system. For each patient, 8 Conventional plans (3, 4, 5 and 6 Fields) and one 3D-CRT plan were prep...
متن کاملAssessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot, Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer
Introduction: Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of radiation oncology, biology, physics
دوره 45 5 شماره
صفحات -
تاریخ انتشار 1999