Correlation of breath ammonia with blood urea nitrogen and creatinine during hemodialysis.

نویسندگان

  • L R Narasimhan
  • W Goodman
  • C K Patel
چکیده

We have spectroscopically determined breath ammonia levels in seven patients with end-stage renal disease while they were undergoing hemodialysis at the University of California, Los Angeles, dialysis center. We correlated these measurements against simultaneously taken blood samples that were analyzed for blood urea nitrogen (BUN) and creatinine, which are the accepted standards indicating the level of nitrogenous waste loading in a patient's bloodstream. Initial levels of breath ammonia, i.e., at the beginning of dialysis, are between 1,500 ppb and 2,000 ppb (parts per billion). These levels drop very sharply in the first 15-30 min as the dialysis proceeds. We found the reduction in breath ammonia concentration to be relatively slow from this point on to the end of dialysis treatment, at which point the levels tapered off at 150 to 200 ppb. For each breath ammonia measurement, taken at 15-30 min intervals during the dialysis, we also sampled the patient's blood for BUN and creatinine. The breath ammonia data were available in real time, whereas the BUN and creatinine data were available generally 24 h later from the laboratory. We found a good correlation between breath ammonia concentration and BUN and creatinine. For one of the patients, the correlation gave an R(2) of 0.95 for breath ammonia and BUN correlation and an R(2) of 0.83 for breath ammonia and creatinine correlation. These preliminary data indicate the possibility of using the real-time breath ammonia measurements for determining efficacy and endpoint of hemodialysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Point of care monitoring of hemodialysis patients with a breath ammonia measurement device based on printed polyaniline nanoparticle sensors.

A device for measuring human breath ammonia was developed based on a single use, disposable, inkjet printed ammonia sensor fabricated using polyaniline nanoparticles. The device was optimized for sampling ammonia in human breath samples by addressing issues such as variations in breath sample volume, flow rate, sources of oral ammonia, temperature and humidity. The resulting system was capable ...

متن کامل

Evaluation of the effect of exercise on serum creatinine and urea nitrogen in hemodialysis patients

Introduction. Chronic renal failure is a progressive disease in which kidney function is impaired, so that the body can not metabolize and maintain fluid balance and electrolytes. Therefore, the present study investigated changes in serum creatinine and urea nitrogen in hemodialysis patients in response to exercise. Materials and Methods. The subjects of this study were dialysis patients who we...

متن کامل

Real-time monitoring of breath ammonia during haemodialysis: use of ion mobility spectrometry (IMS) and cavity ring-down spectroscopy (CRDS) techniques.

BACKGROUND The diffusion of high-performance analytical technology has opened prospects for breath diagnosis as a non-invasive diagnostic tool. In this study, ion mobility spectrometry (IMS) and cavity ring-down spectroscopy (CRDS) techniques were used to analyse ammonia gas (NH3) in real-time in breath from patients undergoing haemodialysis (HD) treatment and any correlation with blood urea ni...

متن کامل

Association of Helicobacter pylori infection and serum albumin in patients on hemodialysis.

INTRODUCTION. Helicobacter pylori infection in gastric mucosa may cause systemic inflammatory reaction. We investigated the inflammatory effect of H pylori infection on nutritional factors such as serum albumin in hemodialysis patients and influence of eradication of H pylori on this association. MATERIALS AND METHODS. Ninety-eight patients on hemodialysis were divided into 2 groups according t...

متن کامل

Predictive factors of restless leg syndrome in hemodialysis patients

INTRODUCTION The restless leg syndrome (RLS) is a neurologic disorder suffering the hemodialysis patients. Although the pathophysiology of this syndrome remains unknown yet, an investigation of the parameters pertinent to it may help to develop the related medical knowledge and to improve the therapeutic-care interventions in this regard. OBJECTIVES The correlation between the RLSs on individ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Proceedings of the National Academy of Sciences of the United States of America

دوره 98 8  شماره 

صفحات  -

تاریخ انتشار 2001