Hyperspectral imaging for early detection of oxygenation and perfusion changes in irradiated skin.
نویسندگان
چکیده
Studies examining acute oxygenation and perfusion changes in irradiated skin are limited. Hyperspectral imaging (HSI), a method of wide-field, diffuse reflectance spectroscopy, provides noninvasive, quantified measurements of cutaneous oxygenation and perfusion. This study examines whether HSI can assess acute changes in oxygenation and perfusion following irradiation. Skin on both flanks of nude mice (n=20) was exposed to 50 Gy of beta radiation from a strontium-90 source. Hyperspectral images were obtained before irradiation and on selected days for three weeks. Skin reaction assessment was performed concurrently with HSI. Desquamative injury formed in all irradiated areas. Skin reactions were first seen on day 7, with peak formation on day 14, and resolution beginning by day 21. HSI demonstrated increased tissue oxygenation on day 1 before cutaneous changes were observed (p<0.001). Further increases over baseline were seen on day 14, but returned to baseline levels by day 21. For perfusion, similar increases were seen on days 1 and 14. Unlike tissue oxygenation, perfusion was decreased below baseline on day 21 (p<0.002). HSI allows for complete visualization and quantification of tissue oxygenation and perfusion changes in irradiated skin, and may also allow prediction of acute skin reactions based on early changes seen after irradiation.
منابع مشابه
A hyperspectral vessel image registration method for blood oxygenation mapping
Blood oxygenation mapping by the means of optical oximetry is of significant importance in clinical trials. This paper uses hyperspectral imaging technology to obtain in vivo images for blood oxygenation detection. The experiment involves dorsal skin fold window chamber preparation which was built on adult (8-10 weeks of age) female BALB/c nu/nu mice and in vivo image acquisition which was perf...
متن کاملImproving the RX Anomaly Detection Algorithm for Hyperspectral Images using FFT
Anomaly Detection (AD) has recently become an important application of target detection in hyperspectral images. The Reed-Xialoi (RX) is the most widely used AD algorithm that suffers from “small sample size” problem. The best solution for this problem is to use Dimensionality Reduction (DR) techniques as a pre-processing step for RX detector. Using this method not only improves the detection p...
متن کاملHyperspectral Imaging as an Early Biomarker for Radiation Exposure and Microcirculatory Damage
BACKGROUND Radiation exposure can lead to detrimental effects in skin microcirculation. The precise relationship between radiation dose received and its effect on cutaneous perfusion still remains controversial. Previously, we have shown that hyperspectral imaging (HSI) is able to demonstrate long-term reductions in cutaneous perfusion secondary to chronic microvascular injury. This study chara...
متن کاملAssociation between cumulative radiation dose, adverse skin reactions, and changes in surface hemoglobin among women undergoing breast conserving therapy
Introduction Radiation therapy is crucial to effective cancer treatment. Modern treatment strategies have reduced possible skin injury, but few clinical studies have addressed the dose relationship between radiation exposure and skin reaction. This prospective clinical study analyzes skin oxygenation/perfusion in patients undergoing fractionated breast conserving therapy via hyperspectral imagi...
متن کاملImpact of linear dimensionality reduction methods on the performance of anomaly detection algorithms in hyperspectral images
Anomaly Detection (AD) has recently become an important application of hyperspectral images analysis. The goal of these algorithms is to find the objects in the image scene which are anomalous in comparison to their surrounding background. One way to improve the performance and runtime of these algorithms is to use Dimensionality Reduction (DR) techniques. This paper evaluates the effect of thr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical optics
دوره 17 2 شماره
صفحات -
تاریخ انتشار 2012