Comparison of Locking Titanium Miniplates and Conventional Titanium Miniplates in Treatment of Mandibular Fractures
نویسندگان
چکیده
The goal of fracture management is to restore proper function by union of the fractured segments and restoring the strength, contour defects that might have happened at the time of injury, and controlling infection at the fracture site. 1 The present study were to evaluate and compare the treatment outcome between 2D locking titanium miniplates and conventional 2D miniplates for symphysis, parasymphysis and body fractures in the mandibular region. A total of 30 patients who sustained fracture in the symphysis, parasymphysis and body region were enrolled for this study. The patients were randomly and equally allocated into two groups. Group-A patient fractures were treated by locking titanium plates and Group-B Patient fractures were treated by conventional 2D mini plates. The patients were followed up at 1 month, 3 months and 6 months for occlusion, infection, hardware failure, stability of fracture segments, healing and paraesthesia .From the results one patient in Group-A had post-operative complication and none of the patients in Group -B had any complications. From this present study we would like to conclude locking titanium miniplates are an alternative mode of treatment for mandibular symphysis, parasymphysis and body fractures.
منابع مشابه
Three Dimensional Titanium Mini Plates in Management of Mandibular Fractures
The treatment of mandibular fractures has evolved from various forms of wiring, splinting, intermaxillary fixation, rigid fixation, compression plates, and mini plates. But in all this circumastances there is a chance of potential infection and malunion in mandibular fracture site. So in our study we used three dimensional titanium miniplates to stabilize the mandibular fracture site. The 3 D t...
متن کاملComparative evaluation of bite force analytical study following mandibular osteosysthesis using three-dimensional and conventional locking miniplates
AIMS AND OBJECTIVES The aim is to study the effectiveness of 2 mm three-dimensional (3D) titanium miniplates and 2 mm conventional titanium miniplates in osteosynthesis of mandibular fractures by comparing the change in bite force. METHODOLOGY The study comprised forty patients of age group 20-40 years, weighing 55-75 kg having mandibular fractures. Patients were randomly divided into two equ...
متن کاملA biomechanical analysis of titanium miniplates used for treatment of mandibular symphyseal fractures with the finite element method.
OBJECTIVE This study aimed to evaluate the stress distribution and stress shielding effect of titanium miniplates used for the treatment of symphyseal fractures using finite element (FE) analysis. STUDY DESIGN Two 3-D FE models of symphyseal fractured mandibles reduced by technique 1, reduction with a single miniplate, and technique 2, reduction with 2 miniplates, respectively, were developed...
متن کامل3-D locking titanium miniplates in management of mandibular fracture: A prospective clinical study
Purpose: The aim of this follow up clinical study was to evaluate the effectiveness of 2mm, 3-dimentional locking titanium miniplates. Patients and Method: A prospective randomized clinical trial was carried out on 10 patients with mandibular fractures. The patients were evaluated for the operating time, clinical assessment of mobility after fixation, occlusion, adequacy of reduction on postope...
متن کامل3-D locking titanium miniplates in management of mandibular fracture: A prospective clinical study
Purpose: The aim of this follow up clinical study was to evaluate the effectiveness of 2mm, 3-dimentional locking titanium miniplates. Patients and Method: A prospective randomized clinical trial was carried out on 10 patients with mandibular fractures. The patients were evaluated for the operating time, clinical assessment of mobility after fixation, occlusion, adequacy of reduction on postope...
متن کامل