The Accuracy of Four Impression-making Techniques in Angulated Implants Based on Vertical Gap

نویسندگان

  • Abolfazl Saboury
  • Hamid Neshandar Asli
  • Zahra Dalili Kajan
چکیده

Statement of the Problem Precision of the impression taken from implant positions significantly determines accurate fit of implant-supported prostheses. An imprecise impression may produce prosthesis misfit. Purpose This study aimed to evaluate the accuracy of four impression-making techniques for angulated implants by stereomicroscope through measuring the vertical marginal gaps between the cemented metal framework and the implant analog. Materials and Method A definitive cast with two 15° mesially angulated implants served as the standard reference for making all the impressions and later for accuracy evaluation. Four groups of five samples were evaluated: (1) closed-tray snap-fit transfer, (2) open-tray nonsplinted impression coping, (3) metal splinted impression coping, and (4) fabricated acrylic resin transfer cap. A gold-palladium framework was fabricated over the angulated implant abutments, the fit of which was used as reference. The gaps between the metal framework and the implant analogs were measured in sample groups. Corresponding means for each technique and the definitive cast were compared by using ANOVA and post hoc tests. Results The mean marginal gap was 38.16±0µm in definitive cast, 89±19.74µm in group 1, 78.66±20.63µm in group 2, 54.16±24.29µm in group 3, and 55.83±18.30µm in group 4. ANOVA revealed significant differences between the definitive cast and groups 1 and 2, but not with groups 3 and 4 (p< 0.05). Conclusion Vertical gap measurements showed that metal splinted impression coping and fabricated acrylic resin transfer cap techniques produced quite more accurate impressions than closed-tray snap-fit transfer and open-tray nonsplinted impression coping techniques do. The fabricated acrylic resin transfer cap technique seems to be a reliable impression-making method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of impressions with different impression materials in angulated implants.

PURPOSE To evaluate the dimensional accuracy of the resultant (duplicative) casts made from two different impression materials (polyvinyl siloxane and polyether) in parallel and angulated implants. MATERIALS AND METHODS Three definitive master casts (control groups) were fabricated in dental stone with three implants, placed at equi-distance. In first group (control), all three implants were ...

متن کامل

تعیین دقت ثبت ایمپلنت در دو روش تری باز و تری بسته و تعیین ثبت جزئیات سطح دندان حین این قالب‌گیری

Background and Aims: Accurate recording of implant location is required to achieve passive fit and have the implants without stress concentration. The aim of this in-vitro study was to evaluate the dimensional and angular accuracy of open-tray and closed-tray impression techniques using polyether impression material and also to assess the surface detail reproduction of the tooth while impressio...

متن کامل

بررسی مقایسه‌ای تری‌های ‌قالب‌گیری تمام قوس و نیم قوس بر دقت ابعادی و زاویه‌ای قالب‌های تهیه‌ شده از ایمپلنت‌های زاویه‌دار

Background and Aims: Taking impression from angulated implants has always been a great challenge in clinic. In this regard, studies on sectional trays are very few. The aim of this study was to evaluate and compare the dimensional and angular accuracy of impressions using full arch and sectional trays. Materials and Methods: Four implants (4.3 &times; 12 mm) (Implantium, Dentium) were plac...

متن کامل

بررسی تأثیر عمق ایمپلنت بر صحت اتصال ترانسفر ‌‌قالب‌گیری

Background and Aims: The exact placement of impression copings in making accurate prosthesis is very important. In some cases, the implants need to be placed deeply subgingival, which could reduce the direct vision and ultimately reduce the precision of impression copings and subsequently, delivered prosthesis. This would be the cause of multiple complications such as delivery of ill-fitting ...

متن کامل

Cast accuracy obtained from different impression techniques at different implant angulations (in vitro study)

BACKGROUND Angulated implants may result in inaccurate impressions, and the impression technique may affect the accuracy of the definitive cast. This study was designed to compare the dimensional accuracy of casts obtained from three impression techniques for three definitive lower casts with implants at different angulations. METHODS Three Osseolink implants were placed in three reference mo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017