Multi-ion versus single-ion conduction mechanisms can yield current rectification in biological ion channels.
نویسندگان
چکیده
There is clear evidence that the net magnitude of negative charge at the intracellular end of inwardly rectifying potassium channels helps to generate an asymmetry in the magnitude of the current that will pass in each direction. However, a complete understanding of the physical mechanism that links these charges to current rectification has yet to be obtained. Using Brownian dynamics, we compare the conduction mechanism and binding sites in rectifying and non-rectifying channel models. We find that in our models, rectification is a consequence of asymmetry in the hydrophobicity and charge of the pore lining. As a consequence, inward conduction can occur by a multi-ion conduction mechanism. However, outward conduction is restricted, since there are fewer ions at the intracellular entrance and outwardly moving ions must cross the pore on their own. We pose the question as to whether the same mechanism could be at play in inwardly rectifying potassium channels.
منابع مشابه
Simulation study of the transport properties of ions through ion channels serving as primary components of a nanobiosensor
Ion channels are naturally occurring pores through the proteins that regulate the passage of ions and thus maintain the concentration of ions inside and outside the cell. The ion channels control many physiological functions and they can show selectivity for a specific ion. Ion channels are mostly observed in nerve cells and muscle cells. The influx of ions into cells can be regulated by a gate...
متن کاملSimulation study of the transport properties of ions through ion channels serving as primary components of a nanobiosensor
Ion channels are naturally occurring pores through the proteins that regulate the passage of ions and thus maintain the concentration of ions inside and outside the cell. The ion channels control many physiological functions and they can show selectivity for a specific ion. Ion channels are mostly observed in nerve cells and muscle cells. The influx of ions into cells can be regulated by a gate...
متن کاملCollective diffusion model for ion conduction through microscopic channels.
Ion conduction through microscopic channels is of central importance in both biology and nanotechnology. To better understand the current-voltage (I-V) dependence of ion channels, here we describe and prove a collective diffusion model that quantitatively relates the spontaneous ion permeation at equilibrium to the stationary ionic fluxes driven by small voltages. The model makes it possible to...
متن کاملSingle-Walled Carbon Nanotubes: Mimics of Biological Ion Channels
Here we report on the ion conductance through individual, small diameter single-walled carbon nanotubes. We find that they are mimics of ion channels found in natural systems. We explore the factors governing the ion selectivity and permeation through single-walled carbon nanotubes by considering an electrostatic mechanism built around a simplified version of the Gouy-Chapman theory. We find th...
متن کاملIon diode logics for pH control.
Electronic control over the generation, transport, and delivery of ions is useful in order to regulate reactions, functions, and processes in various chemical and biological systems. Different kinds of ion diodes and transistors that exhibit non-linear current versus voltage characteristics have been explored to generate chemical gradients and signals. Bipolar membranes (BMs) exhibit both ion c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biological physics
دوره 40 2 شماره
صفحات -
تاریخ انتشار 2014