Medium-Scale Experiments on Stabilizing Riser-Slug Flow
نویسندگان
چکیده
Original SPE manuscript received for review 24 July 2008. Revised manuscript received for review 11 May 2009. Paper (SPE 120040) peer approved 23 May 2009. Summary This is the second of two papers describing control experiments on a medium-scale slug rig. The first paper (Sivertsen et al. 2009) describes experiments performed on a small-scale laboratory rig built at the Norwegian University of Science and Technology (NTNU) Department of Chemical Engineering. These experiments showed that, despite noisy measurements, it is possible, with feedback control, to “stabilize the flow” (i.e., to achieve reasonably smooth flow in the normally riser-induced severe slug-flow region) using only topside measurements. The question to be answered is whether these results also apply for larger riser systems. In the present paper, we look at some results obtained from a 10-m-high, 3-in.-diameter medium-scale test rig located at the Statoil Research Centre in Porsgrunn, Norway. Several cascade control structures are tested and compared, both with each other and with the results obtained from the small-scale NTNU loop. The rig was also modeled and analyzed using a simple three-state dynamic model. The new experiments were successful and confirm the results of Sivertsen et al. (2009) from the small-scale rig. The valve opening with nonslug flow operation could be increased from approximately 12% with no control to almost 24% with control using topside measurements only. This makes it possible to produce with a larger production rate and increase the total recovery from the producing oil field. The valve opening with control could be further increased to approximately 28% using measurements from the bottom of the riser, but such measurements may not be available in many cases.
منابع مشابه
Investigation of Slug Suppression System in Deepwater Scenario
In pipeline-riser systems, pressure fluctuations which result from the formation of large liquid slugs and gas surges due to operational changes or low mass flow rate from production wells and the profile of pipeline-riser systems often lead to trips at the inlet of the separator; and thereby, the problem causes a a loss of the production.In this study, on a sample deep-water oil field off the ...
متن کاملCascade Control Experiments of Riser Slug Flow Using Topside Measurements
Anti-slug control applied to two-phase flow provides a very challenging and important application for feedback control. It is important because it allows for operation that would otherwise be impossible, and challenging because of the presence of both RHP-poles and RHP-zeros. To conduct experiments on pipeline-riser anti-slug control, a small-scale slug-loop has been build. The loop has been mo...
متن کاملAnti-slug control experiments on a small-scale two-phase loop
Anti-slug control applied to two-phase flow provides a very challenging and important application for feedback control. It is important because it allows for operation that would otherwise be impossible, and challenging because of the presence of both RHP-poles and RHP-zeros. To conduct experiments on pipeline-riser anti-slug control, a small-scale slug-loop has been build. The loop has been mo...
متن کاملSimplified dynamic models for control of riser slugging in offshore oil production
Elaborated models such as those used for simulation purposes (e.g. OLGA simulator) cannot be used for model-based control design. The focus of this paper is on deriving simple dynamical models with few state variables that capture the essential behaviour for control. We propose a new simplified dynamic model for severe slugging flow in pipeline-riser systems. The proposed model, together with f...
متن کاملReview of Slug Detection, Modeling and Control Techniques for Offshore Oil & Gas Production Processes
The current offshore oil & gas multi-phase production and transportation installations have big challenges related with the slugging flow: An unstable multi-phase flow regime where the flow rates, pressures and temperatures oscillate in the considered processes. Slug can be caused by different operating conditions and installation structures. The most severe slugs are often induced in long vert...
متن کامل