Reproducibility of up-flow column percolation tests for contaminated soils
نویسندگان
چکیده
Up-flow column percolation tests are used at laboratory scale to assess the leaching behavior of hazardous substance from contaminated soils in a specific condition as a function of time. Monitoring the quality of these test results inter or within laboratory is crucial, especially if used for Environment-related legal policy or for routine testing purposes. We tested three different sandy loam type soils (Soils I, II and III) to determine the reproducibility (variability inter laboratory) of test results and to evaluate the difference in the test results within laboratory. Up-flow column percolation tests were performed following the procedure described in the ISO/TS 21268-3. This procedure consists of percolating solution (calcium chloride 1 mM) from bottom to top at a flow rate of 12 mL/h through softly compacted soil contained in a column of 5 cm diameter and 30 ± 5 cm height. Eluate samples were collected at liquid-to-solid ratio of 0.1, 0.2, 0.5, 1, 2, 5 and 10 L/kg and analyzed for quantification of the target elements (Cu, As, Se, Cl, Ca, F, Mg, DOC and B in this research). For Soil I, 17 institutions in Japan joined this validation test. The up-flow column experiments were conducted in duplicate, after 48 h of equilibration time and at a flow rate of 12 mL/h. Column percolation test results from Soils II and III were used to evaluate the difference in test results from the experiments conducted in duplicate in a single laboratory, after 16 h of equilibration time and at a flow rate of 36 mL/h. Overall results showed good reproducibility (expressed in terms of the coefficient of variation, CV, calculated by dividing the standard deviation by the mean), as the CV was lower than 30% in more than 90% of the test results associated with Soil I. Moreover, low variability (expressed in terms of difference between the two test results divided by the mean) was observed in the test results related to Soils II and III, with a variability lower than 30% in more than 88% of the cases for Soil II and in more than 96% of the cases for Soil III. We also discussed the possible factors that affect the reproducibility and variability in the test results from the up-flow column percolation tests. The low variability inter and within laboratory obtained in this research indicates that the ISO/TS 21268-3 can be successfully upgraded to a fully validated ISO standard.
منابع مشابه
Using selective sequential extraction techniques to evaluate tendency of soil fractions in Cd removal by Fe3O4 nanoparticles in continuous flow system
Use of nanotechnology has proven to be a promising approach toward remediation of all phases of environment. The aim of this work is to investigate the effects of different parameters on using iron III oxide nanoparticles in a continuous flow configuration for the removal of Cd2+ ionsfrom contaminated soils. Also selective sequential extraction tests are carried out to evaluate the nanoparticle...
متن کاملUse of Festuca ovina L. in Chelate Assisted Phytoextraction of Copper Contaminated Soils
Festuca ovina L. is a hyperaccumulating plant which has aroused considerableinterest with respect to its possible use for phytoremediation of contaminated soils. Thisstudy has been conducted to evaluate the potentials of F. ovina L. to serve as aphytoremediation plant in the cleaning up of Cu in the polluted soils and to identifyextraction efficiency of Ethylene Diamine Tetraacetic Acid (EDTA) ...
متن کاملThe Performance of Compost Biofilter for Hydrogen Sulfide Removal from Contaminated Air
In order to evaluate the performance of biofilter for H2S removal from contaminated air, a 120×14 cm column biofilter was constructed using clear polyacrylic material in conjunction with H2S production and control systems. The column was divided into four stages using perforated plates. The column was packed with a mixture of mushroom compost and snail shell (4:1).
 The performance of biofil...
متن کاملThe Performance of Compost Biofilter for Hydrogen Sulfide Removal from Contaminated Air
In order to evaluate the performance of biofilter for H2S removal from contaminated air, a 120×14 cm column biofilter was constructed using clear polyacrylic material in conjunction with H2S production and control systems. The column was divided into four stages using perforated plates. The column was packed with a mixture of mushroom compost and snail shell (4:1). The performance of biofilte...
متن کاملارزیابی باکتری های جدا شده از لجن فعال حاصل از تصفیه فاضلاب شهری منطقه ویژه عسلویه جهت زیست فزونی خاک های آلوده به کروزن
Background and Objectives: Bioaugmentation is a superior technique in bioremediation of contaminated soils with petroleum hydrocarbons. The aim of this study was to evaluate the effect of isolated bacteria from activated sludge of Asalouyeh special zone municipal wastewater treatment for bioaugmentation of kerosene-contaminated soils and to study the growth of isolated bacteria in the presence ...