Safety and efficacy of Cardi-O-fix occluder for percutaneous closure of a patent foramen ovale
نویسندگان
چکیده
BACKGROUND Amplatzer occluder and Cardio-O-fix occluder are currently used in percutaneous closure of patent foramen ovale. However, there is still a lack of relevant reports comparison the differences between them. The aim of this study was to evaluate the short-term and mid-term safety and efficacy of the Cardi-O-fix occluder in preventing recurrent cerebrovascular events in patients with a patent foramen ovale (PFO). METHODS We enrolled 246 patients (105 men) with a PFO from May 30, 2013 to March 30, 2015 in this single-center prospective study. All patients were treated by PFO interventional closure, with the Cardi-O-fix PFO occluder being used in 180 patients and the Amplatzer PFO occluder being utilized in the remaining 66 patients. After the procedure, we verified the safety and efficacy of different devices using contrast transthoracic echocardiography. RESULTS Neither recurrent stroke nor death was encountered during the follow-up of 12 months. Transient ischemic attack (TIA) was noted in 2 patients (1.1%) in the Cardi-O-fix PFO occluder group, and 1 patient suffered from TIA (1.5%) in the Amplatzer PFO occluder group. Among them, only 1 patient exhibited a small right to left shunt (RLS). There was no statistical difference in recurrent cerebral ischemic events. Three cases of paroxysmal atrial fibrillation were observed in the Cardi-O-fix PFO occluder group. One reverted spontaneously to sinus rhythm and the other 2 cases had pharmacologic conversion to sinus rhythm. One case of paroxysmal atrial fibrillation occurred in the Amplatzer group, which underwent pharmacologic conversion to sinus rhythm. There was no significant difference between the 2 groups regarding incidence of arrhythmia. No occluder translocation, erosion, pericardial effusion, and puncture site bleeding were observed in the 2 groups within 12 months of follow-up. The complete closure rates of the Cardi-O-fix and Amplatzer PFO occluder devices at the 12 months after the procedure were 73.9% and 63.6%, respectively, and the effective closure rates were 90.6% and 86.4%, respectively. There was no statistically significant difference in the complete closure rate and effective occlusion rate (P > 0.05) between the devices. CONCLUSIONS There was no significant difference in the short- and mid-term efficacy and safety between the Cardi-O-fix PFO occluder and Amplatzer PFO occluder. The efficacy and safety of the Cardi-O-fix occluder were comparable to those of the Amplatzer PFO occluder.
منابع مشابه
Percutaneous closure of patent foramen ovale: impact of device design on safety and efficacy.
OBJECTIVE To compare the safety and efficacy of percutaneous closure of patent foramen ovale (PFO) with the Amplatzer PFO occluder (Amplatzer) or the PFO STAR device (STAR) in patients with presumed paradoxical embolism. METHODS Implantation characteristics, procedural complications, residual shunt, and recurrence of thromboembolic events were recorded prospectively in 100 consecutive patient...
متن کاملCONGENITAL HEART DISEASE Percutaneous closure of patent foramen ovale: impact of device design on safety and efficacy
Objective: To compare the safety and efficacy of percutaneous closure of patent foramen ovale (PFO) with the Amplatzer PFO occluder (Amplatzer) or the PFO STAR device (STAR) in patients with presumed paradoxical embolism. Methods: Implantation characteristics, procedural complications, residual shunt, and recurrence of thromboembolic events were recorded prospectively in 100 consecutive patient...
متن کاملLong-term follow-up after percutaneous closure of patent foramen ovale with Amplatzer PFO Occluder: a single center experience.
INTRODUCTION Patent foramen ovale (PFO) is associated with the occurrence of cryptogenic strokes, transient neurological ischemic attacks (TIA) and migraine. Therefore despite the recent ambiguous results of prospective controlled trials, percutaneous closure of PFO is still performed in many centers. AIM To evaluate the safety and effectiveness of percutaneous PFO closure in the prevention o...
متن کاملPacemaker lead entrapment complicating transcatheter closure of a patent foramen ovale.
T ranscatheter cardiovascular interventions are nowadays more frequently and safely performed, thus leading to populate the heart with medical devices. Here, we describe an unusual complication following percutaneous closure of a patent foramen ovale (PFO) with an atrial septal occluder. A 52-year-old woman with history of transient ischemic attack was found to have a PFO associated with an atr...
متن کاملRandomized clinical trial comparing percutaneous closure of patent foramen ovale (PFO) using the Amplatzer PFO Occluder with medical treatment in patients with cryptogenic embolism (PC-Trial): rationale and design
BACKGROUND Several studies have shown an association of cryptogenic stroke and embolism with patent foramen ovale (PFO), but the question how to prevent further events in such patients is unresolved. Options include antithrombotic treatment with warfarin or antiplatelet agents or surgical or endovascular closure of the PFO. The PC-Trial was set up to compare endovascular closure and best medica...
متن کامل