On the Stability of Electric Arc Discharges
نویسندگان
چکیده
The stability of electric arc discharges has been explored through the use of an energy balance coupled with charge conservation. In order to facilitate this analysis, a new model for the electrical conductivity function has been proposed. Asymptotic solutions for the arc governing equations have been obtained. Stability criteria have been developed from both the linear theory (infinitesimal size disturbance) and from a minimizing solution point of view for finite size disturbances. The results delineate an open region in the stability diagram where arc instabilities may be possible. Disciplines Engineering | Mechanical Engineering Comments Suggested Citation: Whitman, A.M, Portonovo S. Ayyaswamy and Ira M. Cohen. (1976). On the stability of electric arc discharges. Journal of Applied Physics. Vol 47(11). Copyright (1976) American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics. The following article appeared in Journal of Applied Physics and may be found at http://link.aip.org/link/ JAPIAU/v47/i11/p4827/s1 This journal article is available at ScholarlyCommons: http://repository.upenn.edu/meam_papers/190 On the stability of electric arc discharges A. M. Whitman, P. S. Ayyaswamy, and Ira M. Cohen Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, Pennsylvania 19174 (Received 7 June 1976) The stability of electric arc discharges has been explored through the use of an energy balance coupled with charge conservation. In order to facilitate this analysis, a new model for the electrical conductivity function has been proposed. Asymptotic solutions for the arc governing equations have been obtained. Stability criteria have been developed from both the linear theory (infinitesimal size disturbance) and from a minimizing solution point of view for finite size disturbances. The results delineate an open region in the stability diagram where arc instabilities may be possible. PACS numbers: 52.80.Mg, 52.75.Kq, 52.35.En
منابع مشابه
The Effect of Foamy Slag on Power Consumption in Electric Arc Furnaces
In electric arc furnace steelmaking units, the essential parameters are reducing price, increasing production and decreasing environmental pollution. Electric arc furnaces are the largest users of electric energy in industry. The most important techniques that can be used to reduce the electric energy consumption in electric arc furnaces are scrap preheating, stirring, use of burners and hot ch...
متن کاملThe Effect of Foamy Slag on Power Consumption in Electric Arc Furnaces
In electric arc furnace steelmaking units, the essential parameters are reducing price, increasing production and decreasing environmental pollution. Electric arc furnaces are the largest users of electric energy in industry. The most important techniques that can be used to reduce the electric energy consumption in electric arc furnaces are scrap preheating, stirring, use of burners and hot ch...
متن کاملEFFECT OF ELECTRIC FIELD ON PD ACTIVITY AND DAMAGE INTO SOLID DIELECTRIC MATERIALS
Abstract – In this paper, the effect of applied electric field on the damage due to partial discharges activity into the surroundings dielectrics of a narrow channel encapsulated within the volume of a dielectric material is evaluated using a kinetic model based on Particle in Cell - Monte Carlo Collision (PIC-MCC) model. After application of an electric field across a dielectric material which...
متن کاملRecycling Evaluation of Mill Scale in Electric Arc Furnace
A considerable amount of mill scale is generated from steelmaking plants annually. Although some industries use it as raw material however, since it contains iron in the form of FeO, Fe2O3, and Fe3O4, it can be considered as a valuable metallurgical raw material for iron and steelmaking industry as well. Thus, the aim of this study was to evaluate the possibility, efficiency, and consequences o...
متن کاملA Probabilistic Three-Phase Time Domain Electric Arc Furnace Model based on analytical method
An electric arc furnace (EAF) is known as nonlinear and time variant load that causes power quality (PQ) problems such as, current, voltage and current harmonics, voltage flicker, frequency changes in power system. One of the most important problems to study the EAF behavior is the choice of a suitable model for this load. Hence, in this paper, a probabilistic three-phase model is proposed base...
متن کامل