Evaluation of six immunoassays for detection of dengue virus-specific immunoglobulin M and G antibodies.

نویسندگان

  • J Groen
  • P Koraka
  • J Velzing
  • C Copra
  • A D Osterhaus
چکیده

The performance of six commercially available immunoassay systems for the detection of dengue virus-specific immunoglobulin M (IgM) and IgG antibodies in serum was evaluated. These included two IgM and IgG enzyme immunoassays (EIA) from MRL Laboratories and PanBio, a rapid immunochromatographic test (RIT) from PanBio, immunofluorescence assays (IFA) from Progen, a dot blot assay from Genelabs, and a dipstick EIA from Integrated Diagnostics (INDX). For this study a panel of 132 serum samples, including 90 serum samples from patients with suspected dengue virus infection and 42 serum samples from patients with other viral infections, was used. In addition, serial serum samples from two monkeys experimentally immunized and challenged with dengue virus type 2 were used. Results were considered conclusive when concordant results were obtained with four of the six antibody-specific assays. Based on this definition, the calculated overall agreement for the human serum samples for the respective IgM immunoassays was 97% (128 of 132), with 34% (45 of 132) positive serum samples, 63% (83 of 132) negative samples, and 3% of samples (4 of 132) showing discordant results. The calculated overall agreement for the IgG assays was 94% (124 of 132), with 49% (65 of 132) positive, 45% (59 of 132) negative, and 6% (8 of 132) discordant results, respectively. The sensitivities of the dengue virus-specific assays evaluated varied between 71 and 100% for IgM and between 52 and 100% for IgG, with specificities of 86 to 96% and 81 to 100%, respectively. The relative sensitivities of the respective IgM assays measured with the monkey serum samples were comparable with those obtained with 12 serial serum samples from humans. Overall performance, based on the sum of the agreement, sensitivity, specificity, and Kappa statistics of the IgM and IgG immunoassays, showed that the antibody detection systems from INDX and Genelabs and the MRL and PanBio EIA are useful and reliable assays for dengue virus serodiagnosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sero-epidemiological Study of Herpes simplex virus type 1 infections in outpatient population referred to clinical laboratories in Gorgan, IRAN 2006

Abstract Backgrounds and objectives: Herpes simplex virus type 1 (HSV- 1) infections are mostly shown as a Herpes disease, but It causes conjunctivitis, genital herpes, encephalitis and newborn herpes. This study was conducted to determine the sero-epidemiologic prevalence of herpes simplex virus type 1 in cases referred to clinical laboratories of Gorgan, Iran. Material and methods: In this cr...

متن کامل

Production of a monoclonal antibody against chicken immunoglobulin G: A valuable molecule with research and diagnostic applications

Monoclonal antibodies (MAbs) are invaluable molecules which have several advantages over polyclonal immunoglobulins (Igs) including consistency and higher specificity and hence can be used in biological researches, diagnosis and treatment of diseases. The present study was conducted to produce monoclonal antibody against chicken IgG.TheIgG molecules were purified from chicken serum and used as ...

متن کامل

Comparison of six different commercial IgG-ELISA kits for the detection of TBEV-antibodies.

BACKGROUND Tick-borne encephalitis virus (TBEV) is a pathogenic human flavivirus endemic in some parts of Europe and Asia. Commercial enzyme immunoassays (EIA) for the detection of IgG antibodies are often used in TBEV-seroprevalence studies, as well as for the confirmation of a successful vaccination against TBEV. However, the detection of TBEV-specific antibodies can be biased by the cross-re...

متن کامل

Dengue virus type-3 envelope protein domain III; expression and immunogenicity

Objective(s): Production of a recombinant and immunogenic antigen using dengue virus type-3 envelope protein is a key point in dengue vaccine development and diagnostic researches. The goals of this study were providing a recombinant protein from dengue virus type-3 envelope protein and evaluation of its immunogenicity in mice. Materials and Methods: Multiple amino acid sequences of different i...

متن کامل

APPLICATION OF DOT IMMUNOASSAY (DIA) FOR DETECTION AND TITRATION OF MEASLES VIRUS ANTIBODIES

Measles is one of the most contagious human diseases. Although mass vaccination programs have reduced the incidence of this disease, measles is still an important cause of morbidity and mortality among children in developing countries. Therefore the use of sensitive techniques to evaluate vaccine efficacy and level of immunity among members of susceptible communities is crucial. Serum neut...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical and diagnostic laboratory immunology

دوره 7 6  شماره 

صفحات  -

تاریخ انتشار 2000