The use of Airtraq laryngoscope versus Macintosh laryngoscope and fiberoptic bronchoscope by experienced anesthesiologists.
نویسندگان
چکیده
OBJECTIVE The aim was to compare the hemodynamic parameters, intubation times, upper airway trauma and postoperative sore throat scores of the patients with normal airway anatomy, intubated with the Airtraq, Macintosh laryngoscope and fiberoptic bronchoscope, by experienced anesthesiologists. METHODS Ninety patients, scheduled to undergo elective surgery under general anesthesia were randomly divided into three groups (n = 30): Group A: Airtraq laryngoscope, Group M: Macintosh laryngoscope and Group FB: fiberoptic bronchoscope. The time to intubation and success rates were recorded. The hemodynamic parameters before and one minute after the anesthesia induction were recorded and the measurements were repeated 3, 4 and 5 minutes after the endotracheal intubation. The postoperative sore throat scores and signs of any trauma were also recorded. RESULTS Mean arterial blood pressure and heart rate were not significantly different between the three groups. The mean intubation time interval did not differ between groups. Highest postoperative sore throat scores were recorded at the 6th hour post extubation. The scores were 37.6 +/- 20.9 in Group A, 13.3 +/- 16.8 in Group M and 13.6 +/- 14.0 in Group FB. The scores in Group A were significantly higher compared to other groups. The number of patients requiring additional analgesia to relieve sore throat was also significantly higher in Group A. CONCLUSION The Airtraq laryngoscope seems to be a more traumatic airway device in the routine endotracheal intubation compared to Macintosh laryngoscope and fiberoptic bronchoscope, when used by experienced anesthesiologists. It also does not offer advantage over the first-attempt success rates, the intubation times and hemodynamic parameters.
منابع مشابه
Airtraq(®) laryngoscope-assisted fiberoptic bronchoscope intubation in a child with Pierre-Robin sequence: a case report.
We present a new strategy method of combining use of Airtraq(®) and fiberoptic bronchoscope (FOB) for tracheal intubation in 3-year-old child with Pierre-Robin sequence.
متن کاملEndotracheal intubation in patients with cervical spine immobilization: a comparison of macintosh and airtraq laryngoscopes.
BACKGROUND The Airtraq laryngoscope (Prodol Ltd., Vizcaya, Spain) is a novel single-use tracheal intubation device. The authors compared ease of intubation with the Airtraq and Macintosh laryngoscopes in patients with cervical spine immobilization in a randomized, controlled clinical trial. METHODS Forty consenting patients presenting for surgery requiring tracheal intubation were randomly as...
متن کاملA comparison of tracheal intubation using the Airtraq or the Macintosh laryngoscope in routine airway management: A randomised, controlled clinical trial.
The Airtraq laryngoscope is a novel single use tracheal intubation device. We compared the Airtraq with the Macintosh laryngoscope in patients deemed at low risk for difficult intubation in a randomised, controlled clinical trial. Sixty consenting patients presenting for surgery requiring tracheal intubation were randomly allocated to undergo intubation using a Macintosh (n = 30) or Airtraq (n ...
متن کاملComparison of intubation times using a manikin with an immobilized cervical spine: Macintosh laryngoscope vs. GlideScope vs. fiberoptic bronchoscope
OBJECTIVE Airway management in patients with suspected cervical spine injury is classified as a "difficult airway." The best device for managing difficult airways is not known. Therefore, we conducted an intubation study simulating patients with cervical spine injury using three devices: a conventional Macintosh laryngoscope, a video laryngoscope (GlideScope), and a fiberoptic bronchoscope (MAF...
متن کاملLearning curves of the Airtraq and the Macintosh laryngoscopes for tracheal intubation by novice laryngoscopists: a clinical study.
BACKGROUND The curved laryngoscope blade described by Macintosh in 1943 remains the most widely used device to facilitate tracheal intubation. The Airtraq laryngoscope is a new, single-use device for tracheal intubation. Several studies compared the use of Airtraq and Macintosh laryngoscopes in simulated intubation scenarios on manikins. We evaluated learning and performance of tracheal intubat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Middle East journal of anaesthesiology
دوره 22 5 شماره
صفحات -
تاریخ انتشار 2014