Body fat in neonates and young infants: validation of skinfold thickness versus dual-energy X-ray absorptiometry1–3
نویسندگان
چکیده
Background: There is an interest in noninvasive measurement of body fat in newborns and infants. Measurement of skinfold thickness (SFT) is a simple clinical method. Objective: We correlated fat mass (FM) values of neonates and infants predicted from SFT measurements and compared them with FM values measured by dual-energy X-ray absorptiometry (DXA), a validated in vivo method for determining body fat. Design: The weight, length, body composition (DXA measurement of FM and percentage of body fat), and SFT of 104 healthy term and preterm infants were measured at 0, 2, and 4 mo of age. Results: Mean (± SD) FM determined by DXA increased from 440 ± 220 g at birth to 1310 ± 450 g at 2 mo of age and to 2170 ± 605 g at 4 mo of age. The percentage of body fat increased from 13.3% at birth to 24.5% and 31.2% at 2 and 4 mo of age, respectively. An equation was developed to calculate FM (in g) in newborns by using the sum of SFT measurements (in mm) and body length (l; in cm): FM = 68.2 · SFT0.0162 · l 172.8 (R2 = 0.948, P < 0.001). Conclusions: With the use of statistical bootstrap analysis, the results provide an in vivo validation of SFT measurements against DXA for newborns and young infants. Body fat measurements by SFT correlate with FM values determined by DXA (R2 = 0.936). Estimation of nutritional status is possible with errors (SD) of ± 75, ± 170, ± 300, and ± 380 g for infants with an FM ≤ 500, 501–1000, 1001–2000, or > 2000 g, respectively. Am J Clin Nutr 2002;76:1096–100.
منابع مشابه
Body fat in neonates and young infants: validation of skinfold thickness versus dual-energy X-ray absorptiometry.
BACKGROUND There is an interest in noninvasive measurement of body fat in newborns and infants. Measurement of skinfold thickness (SFT) is a simple clinical method. OBJECTIVE We correlated fat mass (FM) values of neonates and infants predicted from SFT measurements and compared them with FM values measured by dual-energy X-ray absorptiometry (DXA), a validated in vivo method for determining b...
متن کاملAccuracy of a digital skinfold system for measuring skinfold thickness and estimating body fat.
The use of skinfold thickness measurements to evaluate the distribution of subcutaneous adipose tissue and to predict body fat has recognised advantages. However, the different types of skinfold calliper available present limitations that make them unattractive and perhaps less used in daily practice. The purpose of the present study was to evaluate the accuracy and functionality of a new digit...
متن کاملValidation of Simple Epidemiological or Clinical Methods for the Measurement of Body Composition in Young Children
OBJECTIVE The present study aimed to determine the validity of simple epidemiological and clinical methods for the assessment of body fatness in preschool children. METHODS In 89 children (42 boys, 47 girls; mean age 4.1 SD 1.3y) measures of body fatness were made using total body water (TBW), dual energy x-ray absorptiometry (DXA), air displacement plethysmography (BODPOD) and skinfold thick...
متن کاملThe Relationship between Skinfold Thickness and Body Mass Index in Estimating Body Fat Percentage on Bowen University Students
Body Mass Index (BMI) is a weight-to-height ratio used as a quick and easy guide to obesity classification. BMI of 30 or greater is indicative of excess body fat and has been labelled as increasing the risk of degenerative diseases such as cardiovascular disease and diabetes. Body fat percentage is also assessed through skinfold thickness measurement.. The aim of this study was to estimate the ...
متن کاملSuprailiac or abdominal skinfold thickness measured with a skinfold caliper as a predictor of body density in Japanese adults.
Measurement of subcutaneous fat thickness with a skinfold caliper is a simple and inexpensive technique for assessment of body composition, but is influenced by the skin site or the obesity level. The resulting measurement errors may influence the prediction accuracy of body density. We therefore aimed to clarify the characteristics of measurement errors with a skinfold caliper and to determine...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2002